PURPOSE

The OEM Digital Weight Scale is ideal for servicing HVAC and Automotive A/C 

systems. Refrigerant can be measured in standard and metric units and has a 

built in alarm to indicate when the Scale Capacity has been exceeded. 

 

 

The 1990 amendments to the United States Clean Air Act mandate that all 

personnel who service refrigerant systems must be trained and certified. 

Fines are in place for violations and compliance is now being monitored 

by the U.S. EPA. 
Do Not Vent Refrigerant to the Atmosphere. Use Appropriate Recovery 

Equipment. 
Confirm system refrigerant type before servicing vehicle. Cross

contamination of refrigerants can cause damage to A/C system, service 

tools and equipment. Do not blend refrigerants in a system or in the same 

container.

FEATURES

1.  High-visibility .75” x 2.5” LCD Backlit Display

2.  Three units of measure. (kg/oz/Lbs.)

3.  Automatic Shut-off after 10 minutes, backlight will shut off after  

 

3 minutes.

4.  Fully enclosed and removable metal scale platform enables use of  

 

product in or out of the protective case.

5.  The hand held remote Control Head incorporates a 6ft coil cord and a  

 

fold out stand for easy viewing.

6.  Compact, portable, battery operated.

7.  “FULL” Display when weights exceeds the Scale capacity 

 

SETUP

1.  Place the unit on a firm and level service. The platform and Control  

 

Head can be used the case or outside the case.

2.  Remove the Battery Cover from the rear of the Contol Head by  

 

compressing the tab at the base of the Battery Cover.

3.  Insert 9V Battery. Replace the Battery Cover by aligning tabs and  

 

snap into place.

4.  Turn the unit on by pressing the ON/OFF       Button.

5.  Select the unit of measure by selecting the UNIT       Button.

6.  Press the LAMP       Button to activate and deactivate the    

 backlight. 

 

NOTE:

 To prevent damage, remove batteries from the Control Head if 

unit is to be stored for an extended period of time. 

Do Not Leave Dead 

Batteries in the Unit 

Replace the battery if the battery indicator flashes in the top right hand 

corner of the dispay. 

Never Exceed the rated capacity

 

If the display reads “FULL” immediately remove the object being weighed 

from the Scale to prevent damage. 
STATIC DISCHARGE: Climates in some parts of the world are conducive 

to creating static electric build up (ESD). Your scale has been designed to 

eliminate the damaging effects of ESD. In some extreme cases, ESD will 

be apparent on your scale by a lack of response or an inability to turn off 

the unit. In the rare case that this occurs, simply disconnect the battery, 

wait 1 minute and reconnect the battery. The scale will “reboot” itself and 

operate normally once the unit is turned on. 

 

 

 

If the platform is used in the case, make certain nothing touches the case, 

Control Box or platform as false readys can occur.

OPERATION

1.  Press the Z/T       Button to clear and zero the Scale.

2.  Center the Cylinder on the Platform.

3.  Start the charging process by opening the Cylinder and Manifold  

 

Gauge Valves

4.  When charging is complete, close the Cylinder and Manifold Gauge  

 Valves.

5.  Remove the Cylinder from the Scale and press the ON/Off        

 Button.

MAINTENANCE 

1.  Always store the  Digital Refrigerant Scale Set in a well-protected  

 

area where it will not be exposed to inclement weather, corrosive  

 

vapors, abrasive dust, or any other harmful elements.

2.  Keep the  Digital Refrigerant Scale clean for better and safer  

 performance.

3.  Replace 9V Battery as necessary.

Capacity

240 Lbs./110 Kg

Resolution

+/- 0.4Oz/0.02 Lbs./10g

Operating Temp

32° to 122° F

Accuracy

+/-0.5% of Reading

Platform Size

23 cm x 23 cm