Scanner Interface
Appendix A-30
*1
For the flatbed, this setting depends on what is set by the operator panel. For the ADF, this setting
depends on the size detector of the ADF.
Control register B#5
X'00' is set when the power is turned on or when a CLEAR command is issued for initialization.
(g)
Control registers A#6 to A#9
Nonstandard document size setting register
•
The size must be specified in binary in units of 1/400 inch.
Depending on the resolution below, the number of bytes of the document in main scanning direction when
the nonstandard document size is specified for scanning is as follows (without clipping setting):
7
0
6
0
5
4
0
3
0
2
0
1
0
0
0
LSB
Clipping
0 :
Not specified
1 :
Specified
B#5
Document size in sub-scanning
direction
Document size in main scanning
direction
MSB
LSB
A#6
A#7
A#8
A#9
0
7
0 7
0 7
0 7
(A#6, A#7)
400
x
α ÷ 8
byte
(Rounding up to the integer)
α
indicates the output resolution.