A.3 Commands and Response
Appendix A-41
(p)
Extended control register #3
X'00' must be set to this register.
X'00' is set when the power is turned on or CLEAR command is issued for initialization.
A.3.3.3 IMAGE CONTROL command
This command sets the scanner to the operation mode of the image processing circuit.
Byte 1
CNT
Byte 2
CMD
Byte 3
TEXT
Byte 4
or later
X’0x’
X’5A’
Image control
register start
number.
Image control
register
Note:
If this command is sent to the scanner without image processing option (IPC-2D or IPC-3D), the scanner
sends “Operation error” as response.
#3
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
0
LSB
Third byte
7
0
6
5
4
3
2
1
0
LSB
Image control register start number.
Image control register selection
0: Selects image control register A (front side)
1: Selects image control register B (back side)