Scanner Interface
Appendix A-26
(c)
Control register A#2
Control register B#2
X’00’ is set when the power is turned on or when a CLEAR command is issued for initialization.
*1
•
When the built-in pattern is used, the density information shown in the control register A#1/B#1 is valid.
•
4 patterns (000 to 011) are valid when the built-in pattern is selected.
•
When the download pattern is used, the density information shown in Control register A#1/B#1 is
invalid.
•
8 patterns (000 to 111) is valid when the download pattern is selected.
*2
Dithered or Error diffusion are selected by control register A#19/B#19.
*3
This is effective for control register A#2.
*4
Grayscale reading is effective for front-side reading with the resolution of 400dpi or less through third
party slot. Before the duplex reading bit 1 of control register A#2 and B#2 must be set 0.
7
6
5
4
3
2
1
0
0
LSB
MSB
Jam detection when scanning (*3)
0 :
Executed
1 :
Not executed
0 :
Binary reading
1 :
Grayscale reading (*4)
Specifies halftone
0X:
Set from the operator panel
1 0:
Not dithered
1 1:
Dithered or Error Diffusion (*2)
Dither pattern (*1)
0 0 0
0 0 1
0 1 0
0 1 1
1 0 0
1 0 1
1 1 0
1 1 1
Built-in/Download
0 :
Built-in
1 :
Download
Summary of Contents for M3097DE
Page 1: ...C150 E102 01EN M3097DE Image Scanner OEM Manual...
Page 2: ......
Page 4: ...This page is intentionally left blank...
Page 42: ...3 3 Optional image function 3 21...
Page 43: ...Image Functions 3 22 The conceptual image processing flow in the IPC mode is shown below...
Page 45: ...Image Functions 3 24...
Page 70: ...5 3 Cleaning 5 15 Two rollers are included Figure 5 5 Pick roller...
Page 73: ...6 3 Figure 6 1 Jam clearance...
Page 197: ...Scanner Interface Appendix A 124 5 Dimensions of the board For M3093EX DE and M3097DE...