EN
Walter Meier reserves the right to alter specifications.
waltermeier.com
22
INSTRUCTIONS FOR USE
3. Servicing
3.1 Service reminder
The service reminder is activated with preset
time intervals and the ”Service reminder” text
is displayed on the Premium control. As a fac-
tory setting, the service reminder is not in op-
eration. It can be put into operation under the
’Service reminder’ menu point in the ’Install.
and service’ menu. As a standard value, the
service reminder is given at six-month intervals.
The service reminder can be reset to zero from
the ’Install. and service’ menu, ’Alarms’ point.
3.2 To open the ventilation unit
Before you begin any service work, isolate the
power supply voltage to the ventilation unit
by pulling out its electric plug from the wall
socket. Wait a few minutes before you open
the inspection door of the ventilation unit so
that the fans have time to stop and possible air
heaters have time to cool down.
The lock bolts of the inspection doors are
located in the upper and lower edge of the
door under the cover plates. The cover plates
can be removed by shifting them as shown in
the image below.
Open the inspection door by turning the two
lock bolts with a screw driver for slotted screw
heads. The door can then be carefully lifted
away when the lock bolts have been opened.
3.3 Filters
The filters should be checked every three
months for dirt and replaced. Twice per year, the
filters need to be replaced. The filters may need
to be replaced more often in homes where there
is considerable dust or if there are many particles
in the outdoor air.
The ventilation unit must not be operated
without filters. Install only filters recommended by
Swegon in the ventilation unit. Check in the list of
components that you have selected correct filters.
Ventilation unit in the left-hand version;
on the model in the right-hand version,
the components are mirror-inverted.
1. Supply air filter F7
2. Extract air filter F7
3. Heat exchanger protecting plate
4. Protecting plate
5. Protecting plate
1
2
3
5
4
IMPORTANT
Set the fan speeds in accordance
with national regulations when
you commission the ventilation sys-
tem. The system should be commis-
sioned by a qualified person, and
the airflows must not be changed
on one’s own responsibility, since
doing so could disrupt the way the
ventilation system operates.