Clamp pincer CP 10 / CP 20 / CC 20
5
Use of clamp pincer
5
Use of clamp pincer
5.1
Setting up clamp pincer
5.1.1 Manually entering and managing closing data parameters
CAUTION
Possible damage to clamp pincer!
Entering incorrect closing data can cause the clamp pincer to malfunction.
Always enter the correct values for the clamp pincer and pincer head. Observe the specifications and
technical data given by OETIKER.
Requirement:
Battery is charged.
The clamp pincer must be connected to the PC via the USB cable.
NOTICE
The values for pincer model, correlation factor and
closing force tolerance are automatically adopted by the
PC software. These values cannot be changed
manually.
1. Enter the designation of the pincer head in the
"Pincer head" file in the Closing data menu. (max.
18 characters possible)
2. Enter the part number of the pincer head in the
"Pincer head item no." field. (max. 18 characters
possible)
3. Enter the value of the target closing force in the
"Closing force [N]" field.
If the minimum is not met or maximum closing force is
exceeded, the closing force will be automatically
restricted to the minimum/maximum value.
Issue 11.15
08902961
5-18