Clamp pincer CP 10 / CP 20 / CC 20
5
Use of clamp pincer
4. Enter the value of the closing force holding time in
the "Closing force holding time [ms]" field.
5. Click on the “Send data to device” button.
The data is confirmed and transmitted to the clamp
pincer. The status bar shows the progress of data
transmission.
INFO
After every change to the target closing force, the clamp pincer must be calibrated.
Save the input values and calibrate the clamp pincer.
5.1.2 Loading closing data from a file
Requirement:
Battery is charged.
The clamp pincer must be connect to the PC via the USB cable.
The closing data set is available on the PC or data carrier in file format
(.intc)
.
1. Click on the "Read data from file" button in the
Closing data menu.
The folder overview of your PC opens.
2. Select closing data set and click on "Open".
Issue 11.15
08902961
5-19