Clamp pincer CP 10 / CP 20 / CC 20
7
Description of PC software
7.4 Calibration
menu
Fig. 33:
Calibration menu
Calibration of clamp pincer CP 10 / CP 20 / CC 20 is activated in the Calibration menu.
If the device is modified (for instance by attaching a new pincer head – even if the article number is the same) or
if a new target value for the closing force is input, the pincer must be checked.
NOTICE
Possible damage to the clamp pincer and faulty clamp closures!
To ensure uniform and reproducible process quality calibration must be executed at least once per shift or
once per day. Calibration is also necessary if any pincer components are exchanged. OETIKER recommends
checking the closing force after calibration as an additional verification measure. It is critical to ensure that
clamps are not closed in calibration mode.
Calibration is performed in partial processes Initial calibration and Closing force calibration (see also
chapter 5.1.3, p. 5-20).
Initial calibration
Initial calibration is performed at a low initial closing force, so that if the target values deviate grossly from
suitable values there is no risk of damage to the pincer elements or of injury to the user.
Only one measured closure is performed during the course of the initial calibration.