Offgridtec MPPT Pro Duo
Seite
12
von
19
Step5: Connect the remote meter MT11 and AES signal of the refrigerator
❶
RS485 Communication cable
Models
:
CC-RS485-RS485-3.81-4P-150(Included)
CC-RS485-RS485-3.81-4P-1000(Optional)
CC-RS485-RS485-3.81-4P-2000(Optional)
The operation of the remote meter refer to the user
manual of MT11
The controller only provides one AES signal control, and
the practical consideration is needed for the specific
application (Check the “1.5 AES Signal output port
instruction” for more information).
Step6: Power on the controller
The first step, close the BATT2 safety switch and check the BATT2 charging indicator status. The second step, close the
BATT1 safety switch and check the BATT1 charging indicator status (Check the “3. Display Units” for more information).
The last step, close the PV array circuit breaker.
CAUTION: If the controller is not operating properly or the battery indicator on the controller shows an abnormality,
please refer to 5.2 “Troubleshooting.“