4.2 Wire size and circuit breaker
For full power use of the device, batteries with sufficient capacity, as well as battery cables
with corresponding cross-section must be installed. See table.
Line and fuse selection for battery
,Models
12/2000
12/3000
24/3000
Recommended battery capacity (Ah)
200 - 1000
400 - 1200 200 - 700
Empfohlene Gleichstromsicherung
250
350A
250
Recommended line cross-sections (mm
²
)
for + and – connection *, **
0 – 2m
35
50
35
2 – 5m***
2x35
2x50
2x35
*
Follow the local installation rules.
**
Do not place battery cables in a closed cable duct.
*** "2x"
means two positive and two negative cables.
Note: The above wire size and circuit breaker size are for reference only; Please select a suitable
wire and fuse, depending on the current situation
Line and circuit breaker selection for AC output
Models
Cable cross-section
Circuit breaker
PSI-PRO 12/2000
2,5mm
2
/13AWG
AC/2P—16A
PSI-PRO 12/3000
4mm
2
/11AWG
AC/2P—25A
PSI-PRO 24/3000
4mm
2
/11AWG
AC/2P—25A
The mentioned cross-sections and circuit breaker sizen, serve only as a reference;