Officine Gullo
12
EQUIPOTENTIAL
The appliance must be connected to an equipotential system. The connection screw is positioned at the back of the
appliance and is identified by the symbol
.
Attention:
The manufacturer will neither be held responsible for, nor will give any compensation during the guarantee
period for any damage caused, and which is due to inadequate installations not compliant with the instructions.
USER MANUAL
STARTING UP
Before using the appliance for the first time, it is necessary to clean it carefully, especially the water tub (see paragraph
“cleaning and care”).
Check the connection of the appliance and start it up following the instructions.
INSTRUCTIONS FOR USE
Use the appliance only under surveillance.
•
Never start up the appliance without water.
With pasta cookers it is possible to cook pasta, vegetables, rice, eggs, legumes, etc.
TURNING ON
Check that the water drainage tap is closed.
1) Turn on the tap to load the tank to the desired level, which must be higher than the minimum level and do not
exceed the maximum level, which is marked on the tank by the symbol (--)
2) Switch on the main switch installed above the appliance. Turn the control knob from position “0” to the degree of
cooking desired, between 1 (min) and 3 (max).
The white light shows that the heating element is working.
To turn off the appliance, turn the knob into position “O”.
13
Officine Gullo
EMPTYING THE TUB (CVCS...E)
To carry out this operation, it is necessary to open the outlet tap (lever in vertical position) which can only be reached
through the cabinet door situated below the appliance.
EMPTYING THE TUB (CVS4E - CVS6E)
Do not install siphon-type drains. Push the safety device (A) upwards and move lever (B) to open the outlet tap. Once
emptied the tub, close the outlet tap.
ANOMALIES
If the probe does not detect the presence of water in the tank for more than 15 sec. the system disables the heating
element: the alarm is indicated by a flashing red light.
When the probe returns to detect the presence of water, the heating element is activated and the red light is turned off.
NOTE: the filling phase is monitored by the system through the TIME-OUT.