background image

Officine Gullo

10

WIRING DIAGRAM - TOP

   

1.    

Electrical connection

2.    

Push-button starting burner

3/4. 

Power-station starting burner

Fig. E

11

Officine Gullo

DECLARATION OF COMPLIANCE

This appliance is manufactured by OFFICINE GULLO S.r.l

Headquarters and factory

Via Della Torricella 29, Antella, Bagno a Ripoli

50012 Florence - Italy

Tel. +39 055 65 60 3324 

+39 055 62 18 07

officinegullo.com | info@officinegullo.com

The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 2009/142 

for the gas part and with norm 2006/95/CE, 2004/108/CE for the electric part. The installation must be done 

observing the norms in force particularly concerning room ventilation and discharging gas emissions.

N.B.: The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect

installation, alterations, maintenance or use of the appliance, as in all the other cases considered in the items of our 

sales conditions.

GAS TECHNICAL DATA TABLE

MODEL

Dimensions

cm

Burner 

3,5 kW

Burner 

5,5 kW

Burner 

7,5 kW

Coup de 

feu 

7 kW

POWER

Tot. kW

Gas coupling 

ISO 7-1

DFS4P

40 x 70 x 29h

-

1

1

-

13

R1/2GM

D2FS8P

80 x 70 x 29h

1

2

1

-

22

R1/2GM

D3FS12P

120 x 70 x 29h

1

3

2

-

35

R3/4GM

D2FPS12P

120 x 70 x 29h

1

2

1

1

29

R3/4GM

ELECTRIC TECHNICAL DATA TABLE

all models

Power Supply

Tot. power 

(KW)

Max. absorb

A

Power supply 

cable mm²

230V~ 50/60 Hz

0,01

0,04

5x1

Summary of Contents for DFS4P

Page 1: ...INSTRUCTIONS FOR INSTALLATION AND USE DFS4P D3FS12P D2FS8P D2FPS12P GAS HOB FOR RESIDENTIAL AND PROFESSIONAL USE...

Page 2: ...le the appliance s maximum power consumption The use of adapters multiple power boards and extension cords is not recommended 8 When not in use switch off the general power supply to the appliance and...

Page 3: ...RULES FOR CONVERTING AND INSTALLING OTHER TYPES OF GAS 15 CHANGING THE OPEN RING NOZZLES 15 SUBSTITUTING THE NOZZLE IN THE COUP DE FEU BURNER 15 CHECKING FUNCTIONING 16 MAINTENANCE 16 SPARE PARTS 16 U...

Page 4: ...Officine Gullo 4 FIG A 1 DFS4P E Electrical Connection G Gas Connection ISO 7 1 1 2 M INSTALLATION MANUAL...

Page 5: ...5 Officine Gullo Fig A 2 D3FS12P E Electrical Connection G Gas Connection ISO 7 1 3 4 M...

Page 6: ...Officine Gullo 6 Fig A 3 D2FS8P E Electrical Connection G Gas Connection ISO 7 1 1 2 M...

Page 7: ...7 Officine Gullo Fig A 4 D2FPS12P E Electrical Connection G Gas Connection ISO 7 1 3 4 M...

Page 8: ...Bypass By pass four Oven by pass By pass horno FIG F PC GP CF GP FUOCHI FLAMME FEUX COOKING RINGS FUEGOS 562047300M00P00 1 2 3 4 1 Iniettore fuochi Einspritzventil flamme Injecteur feux Injector cook...

Page 9: ...Gullo Fig D Coup de feu 6 FIG K TUTTAPIASTRA GL HPLATTENHERDEN PLAQUE SOLID TOP PLACA 1 Iniettore Einspritzventil Injecteur Injector Inyector 2 Gruppo pilota Z ndBrenner Veilleuse Pilot Piloto 1 Injec...

Page 10: ...Officine Gullo 10 WIRING DIAGRAM TOP 1 Electrical connection 2 Push button starting burner 3 4 Power station starting burner Fig E...

Page 11: ...y concerning room ventilation and discharging gas emissions N B The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect installation alterations main...

Page 12: ...tion of fire and panic Connection and installation of appliance ventilation and exhaust removal systems shall be done according to the Manufacturer s instructions and by qualified technicians and acco...

Page 13: ...nce see technical data table EQUIPOTENTIAL The appliance must be connected to an equipotential system The connection screw is positioned at the back of the appliance and is identified by the symbol At...

Page 14: ...nse blue colour BURNER TECHNICAL DATA TABLE Burner max 3 5 kW min 1 15 kW 12 8 kWh kg G30 BUTANE 30 mbar 12 8 kWh kg G31 PROPANE 37 mbar 9 45 kWh m3st G20 NATURAL GAS H 20 mbar Burner injector 1 100 m...

Page 15: ...are in a packet supplied with the appliance and are marked in hundredths of mm see the technical data table CHANGING THE OPEN RING NOZZLES Main nozzles Take the rungs off remove the burners and trays...

Page 16: ...a symbol which indicates to which burner the knob corresponds To light turn the knob to the left from position 0 to the symbol see figure keep it pushed down and press the button with the symbol unti...

Page 17: ...he desired effect is achieved The brass details should then be dried Do not use polish as this is suitable for maintaining the gloss but not the antique finish and could result in an effect that is no...

Page 18: ...ble manually NATURAL DISCHARGE FORCED DISCHARGE 1 Extractor hood 1 Extractor hood 2 Interlocking Fig 1 Fig 2 WHAT TO DO IN THE EVENT OF A BREAKDOWN Turn off the gas tap and notify the after sales serv...

Page 19: ...19 Officine Gullo...

Page 20: ...Tel 39 055 656 0324 info officinegullo com Via Della Torricella 29 Antella Bagno a Ripoli 50012 Florence Italy OFFICINEGULLO COM en international V 2 3 12 18...

Reviews: