Officine Gullo
14
CHECKING PRIMARY AIR TO THE MAIN BURNERS
All the burners are fitted with an air regulator by means of which the primary air can be varied thanks to an adjustable
bush that can be locked with a screw. In the “Burner Technical Data” table you will find the approximate values for the
“h” parameter (primary air). The flow of primary air must be regulated so there is no detachment of the flame when the
burner is cold or a return of the flame when the burner is hot.
The pilot air is regulated when the appliance is tested and inspected for the gas it is set for.
If you are going to change to a different type of gas, regulate the air by means of the adjusting bush until the flame
stops sputtering and becomes an intense blue colour.
BURNER TECHNICAL DATA TABLE
Burner max 3,5 kW- min. 1,15 kW
12,8 kWh/kg
G30
BUTANE
30 mbar
12,8 kWh/kg
G31
PROPANE
37 mbar
9,45 kWh/m3st.
G20
NATURAL GAS H
20 mbar
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Consumption
Primary air h=mm
90
50
kg/h 0,276
open
90
50
kg/h 0,272
open
145
adjustable
m3 st./h 0,370
open
Burner max 5,5 kW- min. 1,55 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Consumption
Primary air h=mm
115
60
kg/h 0,434
open
115
60
kg/h 0,427
open
175
adjustable
m3 st./h 0,582
20
Burner max 7,5 kW- min. 2,5 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Consumption
Primary air h=mm
135
75
kg/h 0,591
20
135
75
kg/h 0,582
20
205
adjustable
m3 st./h 0,794
20
Burner Coup de Feu 7 kW- min. 4 kW
Burner Injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
130A
100
20
kg/h 0,552
130A
100
20
kg/h 0,544
195
adjustable
35
m3 st./h 0,740
15
Officine Gullo
Burner max 3,5 kW- min. 1,15 kW
G110
8 mbar
G150.1
8 mbar
Town gas
G110
10 mbar
Injector (marking)
By-pass (screw asjustment (number of turns anti-
clockwise from fully closed position)
Air adjustment (mm)
250
1/2
11,0
250
1/2
11,0
235
1/2
11,0
Burner max 5,5 kW- min. 1,55 kW
Injector (marking)
By-pass (screw asjustment (number of turns anti-
clockwise from fully closed position)
Air adjustment (mm)
340
3/4
8,5
340
3/4
8,5
320
3/4
8,5
Burner max 7,5 kW- min. 2,5 kW
Injector (marking)
By-pass (screw asjustment (number of turns anti-
clockwise from fully closed position)
Air adjustment (mm)
450
1+1/2
10,0
450
1+1/2
10,0
390
3+1/2
10,0
RULES FOR CONVERTING AND INSTALLING OTHER TYPES OF GAS
Our appliances are tested and regulated for liquid gas (see plate inside).
The conversion or adaptation to another type of gas must be carried out by a specialized technician. The nozzles
for the various types of gas are in a packet supplied with the appliance and are marked in hundredths of mm (see
the technical data table).
CHANGING THE OPEN RING NOZZLES
Main nozzles
Take the rungs off, remove the burners and trays, with a size 12 spanner substitute the nozzles with the appropriate ones, regulate
the primary air (h) (see the “burner” technical data table) unscrewing the securing screw. Once regulated, tighten the screw, adjust
the minimum flame by turning the screw to the right or left until the thermal power reaches 1,15 kW for the 3,5 kW burner, 1,55
for the 5,5 kW burner and 2,5 kW for the 7 kW burner.
Warning:
If liquid gas is being used the minimum adjustment screw must be locked right down.
SUBSTITUTING THE NOZZLE IN THE COUP DE FEU BURNER
Remove the panel and with a suitable spanner substitute the nozzle with another, suitable one. Adjust the minimum
flame by turning the by-pass screw either to the right or to the left until heat output reaches 4 kW.
The primary air of the all plate burner does not need adjusting.
Attention: If liquid gas is used, the minimum flame adjustment screw must be screwed right down.