CAUTION

1. These safety directions apply to different kinds of appliances. Please identify correctly the specific appliance in 

your possession (check the tag showing the characteristics).

2.  Before using the appliance, read the instruction manual carefully, as it contains important safety information 

on the proper installation, use and maintenance of the appliance. Please keep the instruction manual for further 

reference. 

3.  The appliance’s electrical safety is guaranteed only if the electrical system is earthed in accordance with the 

relevant regulations. It is of the utmost importance to follow such regulations; when in doubt, please consult a 

qualified electrician to have the electrical system thoroughly checked. The manufacturer declines all responsibi

-

lity for damage caused by a badly-earthed electrical system

4.  Before connecting the appliance, make sure that the appliance’s technical characteristics shown on the tag corre-

spond to those of the electrical system and gas distribution network. 

5. Make sure that the electrical system and sockets can handle the appliance’s maximum power consumption as 

shown on the tag. When in doubt, please consult a qualified electrician.

6. The appliance should be connected to the electric supply line by means of an omnipolar switch with a minimum 

contact opening of 3 mm

7.  If the power socket is not compatible with the plug, replace the socket with a proper one and consult a qualified 

electrician to make sure that the cable size can handle the appliance’s maximum power consumption. The use of 

adapters, multiple power boards and extension cords is not recommended.

8.  When not in use, switch off the general power supply to the appliance and close the gas supply valve.

9. Do not obstruct the appliance’s cooling or heat dissipation vents.

10. In case of damage to the appliance’s power cord, it must be replaced exclusively by the manufacturer’s autho-

rized service center.

11. The appliance must be used only for the purposes for which it has been expressly designed (cooking). All other 

uses (such as the heating of a room) are considered inappropriate and therefore dangerous. The manufacturer 

declines all responsibility for damage resulting from improper use of the appliance.

12. The use of any electric appliance implies the observance of some basic rules. More specifically:

A. Do not touch the appliance with wet or damp hands or feet; 

B. Do not use the appliance with bare feet;

C. Avoid the use of extension cords and, if necessary, take all precautions;

D. Do not pull the power cord to disconnect the plug from the power socket;

E. Do not leave the appliance exposed to atmospheric agents (rain, sun, etc.);

F. F. Do not allow children or untrained persons to use the appliance.

13. Before cleaning the appliance or performing maintenance work, disconnect the appliance by pulling the plug out 

of the power socket or turning off the main switch.

14.  In case of failure or malfunction, turn the appliance off, close the gas supply valve and do not attempt to carry 

out any repairs, which must be done exclusively by an authorized service center. 

     Request the use of original spare parts only. Failure to comply with the above recommendations may compromise 

the appliance’s safety 

Summary of Contents for DWFS4

Page 1: ...INSTRUCTIONS for installation and use MAXI BURNER FOR RESIDENTIAL AND PROFESSIONAL USE DWFS4...

Page 2: ...appliance s maximum power consumption The use of adapters multiple power boards and extension cords is not recommended 8 When not in use switch off the general power supply to the appliance and close...

Page 3: ...ild Plaque des caract ristiques Data Plate Chapa de caracter sticas Attacco gas Gasanschluss Raccord gaz Gas Connection Conexi n gas 2 A C A B Targhetta caratteristiche Typenschild Plaque des caract r...

Page 4: ...regulation 3 Pilot 4 Wok ring FIG C 1 Iniettore fuochi Einspritzventil flamme Injecteur feux Injector cooking rings Inyector fuegos 2 Regolazione aria Luftregelung R glage d air Air regulation Regulac...

Page 5: ...5 Officine Gullo 1 Pilot bracket screw 2 Pilot bracket 3 Pilot air bush 4 Pilot Injector 5 Injector screw 6 Spring 7 Thermocouple FIG D 3 7 1 5 4 6 2 H...

Page 6: ...6 Officine Gullo...

Page 7: ...ERS TECHNICAL DATA TABLE 11 RULES FOR CONVERTING AND INSTALLING OTHER TYPES OF GAS 11 SUBSTITUTING THE NOZZLE IN OPEN COOKING RINGS 11 CHECKING FUNCTIONING 12 MAINTENANCE 12 SPARE PARTS 12 INSTRUCTION...

Page 8: ...when connecting the appliance an automatic device enabling the disconnection of all contacts from the mains must be installed above it this device must have a contacts opening of at least 3 mm GAS TE...

Page 9: ...safety at WorkAct 1974 Codes of Practice BS 8173 1982 The Building Regulations 1985 The Building Standards Regulations 1981 the IEE Regulations and the by laws of the local Water Undertaking The loca...

Page 10: ...eat output thermal power is indicated on the data plate of the appliance Firstly check that the appliance can be used with the type of gas supplied then check that the indication on the plate correspo...

Page 11: ...GAS H 20 mbar Burner injector 1 100 mm Min output adjustment 1 100 mm Pilot Injector 1 100 mm Consumption Primary air h mm 155 75 20 kg h 0 788 open 155 75 20 kg h 0 777 open 230 adjustable 30 m3 st h...

Page 12: ...di termocoppie e bruciatori asportando le griglie e le bacinelle ISTRUZIONI PER L USO Attenzione Usare l apparecchio solo sotto sorveglianza PENTOLAME Il pentolame deve essere di tipo wok vedi immagi...

Page 13: ...and neutral detergent then rinsed thoroughly in order to eliminate all traces of detergent after which dried with a dry cloth Do not use abrasive or corrosive detergents The enamelled parts should be...

Page 14: ...nickel plated brass details in order to avoid spoiling the beauty of the nickel plated satin finished solid brass with an artificial patina All the nickel plated and satin finished brass surfaces sho...

Page 15: ...tly to the outside is acceptable Forced Discharge Fig 2 but its capacity must not be inferior to what is esta blished in item 4 3 of the UNI CIG norm 8723 In the event of forced discharge The gas supp...

Page 16: ...WWW OFFICINEGULLO COM V 2 1 10 17 OFFICINE GULLO S R L via della Torricella 29 50012 Antella Bagno a Ripoli FI Tel 39 055 6560324 621807 Fax 39 055 620670 info officinegullo com en INTERNATIONAL...