CHECKING FOR ADEQUATE VENTILATION

Make sure that the air intake into the room where the appliance is installed is sufficient for an 

adequate change of air, as specified by regulations in effect.

The appliances installed in buildings open to the public must satisfy the following requirements.

Installation rules

The installation and maintenance of the appliance must be done according to the correct proce-
dures and regulation

texts in use, particularly:

• safety standards for the prevention of fire and panic.

Connection and installation of appliance, ventilation and exhaust removal systems, shall be done 

according to the Manufacturer’s instructions and by qualified technicians and according to the 

regulations in effect. The electric wiring shall conform to the regulations in effect. 

All fire prevention codes shall be observed.

a) General indications 

(Rules valid for GB only)

- For all appliances:

Gas safety Regulations, 1984; Health and safety at Work Act, 1974 Codes of Practice, BS 8173, 
1982, The Building
Regulations 1985; The Building Standards Regulations, 1981, the IEE Regulations and the by-
laws of the local Water Undertaking.
The local gas Region or LPG supplier and the local authority and the relevant recommendation 
of the British Standards (latest editions) concerned.
The installation, transformation and repair of appliances for professional kitchens as well as re-
moval due to malfunction, and the supply of gas, may be made only by means of a maintenance 

contract stipulated with an authorized sales office and in observance of technical regulations.

The appliance can be installed by itself or in a series side by side with appliances produced by us. 
There must be a minimum distance of at least 10 cm between the appliance and the sides of the 

nearby cabinets made of inflammable material. 

Take suitable measures to guarantee thermal insulation of the inflammable sides, such as, for 

example, the installation of protection against radiation. 
The appliances must be installed in a suitable manner, observing the safety standards. 
The small feet are adjustable to level the appliance.

Summary of Contents for DWFS4

Page 1: ...INSTRUCTIONS for installation and use MAXI BURNER FOR RESIDENTIAL AND PROFESSIONAL USE DWFS4...

Page 2: ...appliance s maximum power consumption The use of adapters multiple power boards and extension cords is not recommended 8 When not in use switch off the general power supply to the appliance and close...

Page 3: ...ild Plaque des caract ristiques Data Plate Chapa de caracter sticas Attacco gas Gasanschluss Raccord gaz Gas Connection Conexi n gas 2 A C A B Targhetta caratteristiche Typenschild Plaque des caract r...

Page 4: ...regulation 3 Pilot 4 Wok ring FIG C 1 Iniettore fuochi Einspritzventil flamme Injecteur feux Injector cooking rings Inyector fuegos 2 Regolazione aria Luftregelung R glage d air Air regulation Regulac...

Page 5: ...5 Officine Gullo 1 Pilot bracket screw 2 Pilot bracket 3 Pilot air bush 4 Pilot Injector 5 Injector screw 6 Spring 7 Thermocouple FIG D 3 7 1 5 4 6 2 H...

Page 6: ...6 Officine Gullo...

Page 7: ...ERS TECHNICAL DATA TABLE 11 RULES FOR CONVERTING AND INSTALLING OTHER TYPES OF GAS 11 SUBSTITUTING THE NOZZLE IN OPEN COOKING RINGS 11 CHECKING FUNCTIONING 12 MAINTENANCE 12 SPARE PARTS 12 INSTRUCTION...

Page 8: ...when connecting the appliance an automatic device enabling the disconnection of all contacts from the mains must be installed above it this device must have a contacts opening of at least 3 mm GAS TE...

Page 9: ...safety at WorkAct 1974 Codes of Practice BS 8173 1982 The Building Regulations 1985 The Building Standards Regulations 1981 the IEE Regulations and the by laws of the local Water Undertaking The loca...

Page 10: ...eat output thermal power is indicated on the data plate of the appliance Firstly check that the appliance can be used with the type of gas supplied then check that the indication on the plate correspo...

Page 11: ...GAS H 20 mbar Burner injector 1 100 mm Min output adjustment 1 100 mm Pilot Injector 1 100 mm Consumption Primary air h mm 155 75 20 kg h 0 788 open 155 75 20 kg h 0 777 open 230 adjustable 30 m3 st h...

Page 12: ...di termocoppie e bruciatori asportando le griglie e le bacinelle ISTRUZIONI PER L USO Attenzione Usare l apparecchio solo sotto sorveglianza PENTOLAME Il pentolame deve essere di tipo wok vedi immagi...

Page 13: ...and neutral detergent then rinsed thoroughly in order to eliminate all traces of detergent after which dried with a dry cloth Do not use abrasive or corrosive detergents The enamelled parts should be...

Page 14: ...nickel plated brass details in order to avoid spoiling the beauty of the nickel plated satin finished solid brass with an artificial patina All the nickel plated and satin finished brass surfaces sho...

Page 15: ...tly to the outside is acceptable Forced Discharge Fig 2 but its capacity must not be inferior to what is esta blished in item 4 3 of the UNI CIG norm 8723 In the event of forced discharge The gas supp...

Page 16: ...WWW OFFICINEGULLO COM V 2 1 10 17 OFFICINE GULLO S R L via della Torricella 29 50012 Antella Bagno a Ripoli FI Tel 39 055 6560324 621807 Fax 39 055 620670 info officinegullo com en INTERNATIONAL...

Reviews: