Keep the appliance area free and clear from combustibles.
Not obstruct the flow of combustion and ventilation air.
This manual shall be retained for future reference.
The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect
installation, alterations, maintenance or use of the appliance, as in all the other cases considered in the items of our
sales conditions.
GAS PRESSURE REGULATOR
(Must be installed)
Each gas hook input (every element) is supplied with a separate pressure regulator that needs to be installed.
WARNING: Maximum input pressure is ½ PSI
The gas pressure regulator has to be placed back to the wall or behind the cabinetry next to the range, never
under it, connected with a flexible gas connecting hose.
For assembly proceed as follows:
• Fix the 90° elbow (1) to the income gas ramp.
•
Connect the flexible gas connecting hose (min lenght 39") to the elbow.
• Screw in the nipple piece (2) to the pressure regulator (3).
•
Connect the flexible hose to the nipple piece
.