RULES FOR CONVERTING AND INSTALLING FOR  OTHER TYPES OF GAS

Our appliances are tested and regulated with liquid gas (see data plate).

The conversion or adaptation to another type of gas must be carried out by a specialized technician. The nozzles 

for the various types of gas are supplied in a packet and are marked in hundredths of mm (see “burners” technical 

data table).

REPLACING THE NOZZLE FOR THE BURNERS

Remove the grills, the burners and the containers, substitute the nozzles with the right ones, using a suitable spanner, 

unscrewing the blockage screw and relative jam nut. 

Once regulated, tighten the screw, adjust the minimum flame by turning the screw to the right or left until the the 

thermal power reaches 3,924 BTU/h for the 11,942 BTU/h burner, 5,118 BTU/h for the 18,767 BTU/h burner 

and 8,530 BTU/h for the 25,591 BTU/h burner.

Warning: 

For functioning with LPG, the screw for regulating minimum output must be blocked completely.

DECLARATION OF COMPLIANCE

The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 90/396 for 

the gas part and with norm 73/23 for the electric part. The installation must be done observing the norms in force 

particularly concerning room ventilation and discharging gas emissions.

N.B.: 

The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect

installation, maintenance or use of the appliance and alterations, as in all the other cases considered in the items of

our sales conditions.

ELECTRIC CONNECTION

WARNING

: All electrical work must be performed by a qualified electrician.

Please ensure that the appropriate electrical codes or prevailing local building codes and ordinances are adhered 

to.

Ensure that the electricity supply is disconnected at source. Do not use an extension cord or adapter plug with this 

appliance.

This appliance must be grounded. Connect to a properly grounded branch circuit, protected by an appropriate 

circuit breaker.

Electrical Supply. 

This  appliance  requires  electrical  supply  –  ensure  an  appropriately  qualified  person  completes  the  electrical 

connection.

The appliance must be connected to an equipotential system. The connection screw is

positioned at the back of the appliance and is identified by the symbol 

Attention!

 the manufacturer cannot be held responsible for, and does not cover in the guarantee any damage 

resulting from bad or faulty connections.

The appliance may be supplied without  the connection cable. In this case, the connection cable must have the 

following characteristics: it must be type H05RNF and must have an adequate section for the power of the appliance 

(see technical data table).

21

Officine Gullo

To install, proceed in the following way:

-Remove the back panel bye removing the screws that are around its perimeter as shown in picture 1E;

-Fit the connection cable through the cable channel, connect the conductor wires to the corresponding terminals in

the junction box as shown in picture 2E below and fix them into place.

-Block the cable with the cable blocker, and reassemble the panel. The ground wire must be longer than the others

so that if the cable blocker should break for any reason, it will disconnect after the hot wires.

The installation of this appliance must conform with all applicable local codes. In the absence of local codes, the 

installation must conform to the latest level of the National Electric Code, ANSI/NFPA 70.

Picture  2E

There are several screws around the 

perimeter of the back panel, to remove the 

panel you need to remove all the screws 

around the perimeter and them pull away 

the panel to access the terminal block. 

IMPORTANT ! MAKE SURE TO ALWAYS 

DISCONNECT THE APPLIANCE FROM 

THE ELECTRICITY BEFORE WORKING 

ON IT.

Picture  1E

Summary of Contents for GES8MPU

Page 1: ...INSTRUCTIONS FOR INSTALLATION AND USE GES8MPU GAS RANGE WITH ELECTRIC OVEN FOR RESIDENTIAL AND PROFESSIONAL USE...

Page 2: ...Officine Gullo 2...

Page 3: ...N 17 IMPORTANT 17 PIPE FOR GAS CONNECTION 17 CHECKING HEAT OUTPUT 18 ADJUSTMENTS IN MAIN BURNERS 19 BURNERS TECHNICAL DATA TABLE ADJUSTMENT VALUES 19 RULES FOR CONVERTING AND INSTALLING FOR OTHER TYPE...

Page 4: ...r its intended purpose as described in this manual To ensure proper and safe operation Appliance must be properly installed and grounded by a qualified technician DO NOT attempt to adjust repair servi...

Page 5: ...E OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND C...

Page 6: ...c shock If the appliance is defective immediately turn the appliance off and discontinue use Disconnect the range from the gas and power supply and contact the assistance If the range is installed beh...

Page 7: ...urface cooking operation unattended especially when using a high heat setting or when deep fat frying Boilovers cause smoking and greasy spillovers may ignite Clean up greasy spills as soon as possibl...

Page 8: ...heet When using an electrical appliance e g a hand mixer near the cooktop make sure that the power cable does not come into contact with the hot cooktop The cable s insulation could become damaged Coo...

Page 9: ...ching or cleaning them DO NOT touch the burner grates or surrounding areas until they have had sufficient time to cool Clean appliance with caution Use care to avoid steam burns if a wet sponge or clo...

Page 10: ...o Backofen Bypass By pass four Oven by pass By pass horno FIG F PC GP CF GP FUOCHI FLAMME FEUX COOKING RINGS FUEGOS 562047300M00P00 1 2 3 4 1 Iniettore fuochi Einspritzventil flamme Injecteur feux Inj...

Page 11: ...codes In the absence of local codes the installation must conform to the latest level of the National Electric Code ANSI NFPA 70 If the electrical supply is not turned on or is interrupted the applian...

Page 12: ...ion box Tablero de bornes 4 Resistenza Widerstand R sistance Element Resistencia 5 Spia bianca wei e Kontroll Leuchte T moin blanc White light Luz indicadora blanca 6 Spia verde gr ne Kontroll Leuchte...

Page 13: ...mproper or incorrect installation alterations maintenance or use of the appliance as in all the other cases considered in the items of our sales conditions GAS PRESSURE REGULATOR Must be installed Eac...

Page 14: ...gas regulator 1 Unscrew the hex nut 2 Choose the proper gas regulator NAT natural gas LP LPG NAT set for natural gas LP set for LPG 3 Insert the gas regulator in the chosen side in the hex cap 4 Put...

Page 15: ...for a variety of reasons Under no circumstances should the factory supplied regulator be removed or by passed 8 The factory supplied pressure regulator will withstand an input pressure of PSI 13 iwc...

Page 16: ...le mm GES8MPU 80x70x90h 5 21 74 110 110V 50 60 Hz 3 x 2 5 MODEL DIMENSIONS cm NOMINAL BURNER CAPACITY TOT NOM CAPACITY Gas coupling NPT Nr Open ring 11 942 BTU h Nr Open ring 18 767 BTU h Nr Open ring...

Page 17: ...with other appliances of our production It is necessary to observe a minimum distance of 4 10 cm from the appliance to prevent contact with walls of inflammable material adequate measures must also b...

Page 18: ...Figure A Read the pressure with a gauge inserted in the relative pressure outlet see figure A Remove the hermetically closed screw and connect the gauge pipe After reading put back the screw tightenin...

Page 19: ...lues note that for LPG the screw position should be closed GAS A Natural gas pressure at the outlet of the regulator 10 mbar 4 inch water GAS E Propane gas pressure at the outlet of the regulator 24 9...

Page 20: ...ilation and discharging gas emissions N B The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect installation maintenance or use of the appliance an...

Page 21: ...r than the others so that if the cable blocker should break for any reason it will disconnect after the hot wires The installation of this appliance must conform with all applicable local codes In the...

Page 22: ...JUSTING THE ELECTRIC OVEN Before turning the oven on make sure the oven racks are in the desired position Turn the control knob to the right and set the temperature wanted To turn the oven on turn the...

Page 23: ...ce metal polishes are abrasive and it will take away some of the chrome plating with each use Cleaning burnished brass surfaces The antiquing finish of the surface Burnished Brass is the result of nat...

Page 24: ...fact our brushed stainless steel finish is accomplished by millions of little scratches But in the event that you have a deep scratch that you want to care for the surfaces can always be re brushed u...

Page 25: ...25 Officine Gullo...

Page 26: ...Officine Gullo 26...

Page 27: ...27 Officine Gullo...

Page 28: ...Tel 39 055 656 0324 info officinegullo com Via Della Torricella 29 Antella Bagno a Ripoli 50012 Florence Italy OFFICINEGULLO COM us V 2 7 12 20...

Reviews: