Officine Gullo
20
RULES FOR CONVERTING AND INSTALLING FOR OTHER TYPES OF GAS
Our appliances are tested and regulated with liquid gas (see data plate).
The conversion or adaptation to another type of gas must be carried out by a specialized technician. The nozzles
for the various types of gas are supplied in a packet and are marked in hundredths of mm (see “burners” technical
data table).
REPLACING THE NOZZLE FOR THE BURNERS
Remove the grills, the burners and the containers, substitute the nozzles with the right ones, using a suitable spanner,
unscrewing the blockage screw and relative jam nut.
Once regulated, tighten the screw, adjust the minimum flame by turning the screw to the right or left until the the
thermal power reaches 3,924 BTU/h for the 11,942 BTU/h burner, 5,118 BTU/h for the 18,767 BTU/h burner
and 8,530 BTU/h for the 25,591 BTU/h burner.
Warning:
For functioning with LPG, the screw for regulating minimum output must be blocked completely.
DECLARATION OF COMPLIANCE
The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 90/396 for
the gas part and with norm 73/23 for the electric part. The installation must be done observing the norms in force
particularly concerning room ventilation and discharging gas emissions.
N.B.:
The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect
installation, maintenance or use of the appliance and alterations, as in all the other cases considered in the items of
our sales conditions.
ELECTRIC CONNECTION
WARNING
: All electrical work must be performed by a qualified electrician.
Please ensure that the appropriate electrical codes or prevailing local building codes and ordinances are adhered
to.
Ensure that the electricity supply is disconnected at source. Do not use an extension cord or adapter plug with this
appliance.
This appliance must be grounded. Connect to a properly grounded branch circuit, protected by an appropriate
circuit breaker.
Electrical Supply.
This appliance requires electrical supply – ensure an appropriately qualified person completes the electrical
connection.
The appliance must be connected to an equipotential system. The connection screw is
positioned at the back of the appliance and is identified by the symbol
Attention!
the manufacturer cannot be held responsible for, and does not cover in the guarantee any damage
resulting from bad or faulty connections.
The appliance may be supplied without the connection cable. In this case, the connection cable must have the
following characteristics: it must be type H05RNF and must have an adequate section for the power of the appliance
(see technical data table).
21
Officine Gullo
To install, proceed in the following way:
-Remove the back panel bye removing the screws that are around its perimeter as shown in picture 1E;
-Fit the connection cable through the cable channel, connect the conductor wires to the corresponding terminals in
the junction box as shown in picture 2E below and fix them into place.
-Block the cable with the cable blocker, and reassemble the panel. The ground wire must be longer than the others
so that if the cable blocker should break for any reason, it will disconnect after the hot wires.
The installation of this appliance must conform with all applicable local codes. In the absence of local codes, the
installation must conform to the latest level of the National Electric Code, ANSI/NFPA 70.
Picture 2E
There are several screws around the
perimeter of the back panel, to remove the
panel you need to remove all the screws
around the perimeter and them pull away
the panel to access the terminal block.
IMPORTANT ! MAKE SURE TO ALWAYS
DISCONNECT THE APPLIANCE FROM
THE ELECTRICITY BEFORE WORKING
ON IT.