To install, proceed in the following way:
-Remove the back panel bye removing the screws that are around its perimeter as shown in picture 1E;
-Fit the connection cable through the cable channel, connect the conductor wires to the corresponding terminals in
the junction box as shown in picture 2E below and fix them into place.
-Block the cable with the cable blocker, and reassemble the panel. The ground wire must be longer than the others
so that if the cable blocker should break for any reason, it will disconnect after the hot wires.
The installation of this appliance must conform with all applicable local codes. In the absence of local codes, the
installation must conform to the latest level of the National Electric Code, ANSI/NFPA 70.
Picture 2E
There are several screws around the
perimeter of the back panel, to remove the
panel you need to remove all the screws
around the perimeter and them pull away
the panel to access the terminal block.
IMPORTANT ! MAKE SURE TO ALWAYS
DISCONNECT THE APPLIANCE FROM
THE ELECTRICITY BEFORE WORKING
ON IT.
Picture 1E