Regulations 1985; The Building Standards Regulations, 1981, the IEE Regulations and the by-
laws of the local Water Undertaking.
The local gas Region or LPG supplier and the local authority and the relevant recommendation
of the British Standards (latest editions) concerned.
The installation, transformation and repair of appliances for professional kitchens as well as re-
moval due to malfunction, and the supply of gas, may be made only by means of a maintenance
contract stipulated with an authorized sales office and in observance of technical regulations.
The appliance can be installed by itself or in a series side by side with appliances produced by us.
There must be a minimum distance of at least 10 cm between the appliance and the sides of the
nearby cabinets made of inflammable material.
Take suitable measures to guarantee thermal insulation of the inflammable sides, such as, for
example, the installation of protection against radiation.
The appliances must be installed in a suitable manner, observing the safety standards.
The small feet are adjustable to level the appliance.
PIPE FOR GAS CONNECTION
The gas connection must be done with steel or copper pipes, or otherwise with flexible steel
pipes in compliance with the national norms, if any exist. Each appliance must be provided
with a cut-off cock for rapid interruption of the gas supply. Once the appliance has been
installed, it is necessary to check for gas leaks for the pipe fittings; do not use a flame for
this purpose but a non-corrosive substance such as soapy water or foamy substances as
contained in leakfinder sprays. All our appliances undergo careful testing: the type of gas,
the operating pressure and the category are indicated on the data plate.
NB:
The year of the appliance manufacture is shown in item “N” on the data plate. The first
two numbers (e.g. 08..) represent the year of manufacture.
ELECTRIC CONNECTION
The appliance is supplied without the connection cable; to install it, proceed in the fol-
lowing way:
- Remove the back panel
- Push the connection cable through the cable channel, connect the conductor wires to the
corresponding terminals in the junction box and fix them into place.
- Block the cable with the cable blocker, and reassemble the panel. The earth wire must be
longer than the others so that if the cable blocker should break, it will disconnect after the
tension wires.
N.B. The connection cable must have the following characteristics: it must be type
H05RN-F and must have an adequate section for the power of the appliance (see tech
-
nical data table).