INSTRUCTION MANUAL
2 CHANNEL FX TIMER
is activated, press the “auto run” button (11) to disable it, and then press two times the “stop/
reset” button (9).
3. Connect the device (s) you want to control to the POWER OUT connectors (7). The 2 CHANNEL FX
TIMER supports up to 20A resistive load, or 15A inductive load. Make sure that the consumption
of
all
machines which will be activated at the same time does not exceed the maximum allowed.
4.
Confi gure the activation times of the two channels. To set them, press the “select” button (10)
on the output which you want to confi gure (OUT1 or OUT2) until the time units blinks. The units
shown on the screen are hh/mm/ss/cs. To modify the value of the units, press “up” and “down”
buttons while the units are blinking. Press the “select” button (10) to move to the next unit.
Once you have defi ned the hundredths of a second, press “select” (10) again to end the process.
5.
Now you can press the “Start / Pause Button” button (8) to start the timer process. When you
start the process, it activates fi rstly the “OUT 1” channel with the duration defi ned in step 4. At
the end of this defi ned cycle time in OUT1, the “OUT2” channel will be activated. And when the
time defi ned in “out2” is fi nished, the process ends.
6. To start the process again, press the “start/pause” (8) button again.
7. PAUSE FUNCTION “ON”: To pause the cyclic process during the operation, press the “start/
pause” button (8). The process will then stop leaving ON/activated the channel that was turned
on. Press again the “start/pause” button (8) to resume the process.
8.
PAUSE FUNCTION “OFF”: To pause the cyclic process during the operation, press the “start/
pause” button (9). The process will then stop leaving Off /disactivated the channel that was
turned on. Press again the “start/pause” button (8) to resume the process.
9.
CYCLIC FUNCTION: Press the “Loop” button (12) at any time whenever the process repeats
cyclically.
10.
AUTO-RUN FUNCTION: Press the “Auto run” button (11) so that the 2 CHANNEL FX TIMER
automatically starts the program when powered on.
IMPORTANT:
If you want to make a continuous use of the 2 CHANNEL FX TIMER device (more than 24 hours), make
sure that the activation times are longer than 10 seconds. A prolonged use of the device (more than
24h) with a short activation cycles, may overheat the device and have a bad function. In case of a
malfunction by overheating, turn off the device for about 30 minutes before turning it on again.
1.
Coloque el 2 CHANNEL FX TIMER en una superfi cie llana y estable. Conecte la alimentación
de corriente mediante el conector powercon de entrada (1). Asegúrese de que el cable de
alimentación admite la potencia de la/s máquina/s de FX que quiere controlar.
2.
Si utiliza el dispositivo por primera vez, encienda el 2 CHANNEL FX TIMER mediante el interruptor
de encendido (3) y asegúrese de que la función “auto run”(11) está desactivada. Si la función
está activada, pulse el botón de “auto run” (11) para desactivarla y seguidamente pulse dos
veces el botón “stop/reset” (9).
3. Conecte el/los dispositivo/s a controlar a la/s toma/s de salida de corriente (power out) (7). El 2
CHANNEL FX TIMER soporta hasta 20A de carga resistiva o 15A de carga inductiva.
4.
Confi gure los tiempos de encendido de los dos canales. Para confi gurarlos pulse el botón
“select” (10) de la salida que quiere confi gurar hasta que las unidades que desea cambiar
parpadeen. Las unidades en pantalla son hh/mm/ss/cs. Para variar el valor de las unidades
pulse los botones “up” y “down” mientras las unidades parpadean. Pulse de nuevo el botón
“select” (10) para pasar a la siguiente unidad. Una vez tenga defi nidas las centésimas de
segundo vuelva a pulsar “select”(10) para fi nalizar el proceso.
5.
Pulse el botón “start” (8) para iniciar el proceso. Al iniciar el proceso se activa el canal “out 1”
con la duración que se le haya determinado. Al fi nalizar el tiempo de activación del “out 1” se
pone en marcha el canal “out 2”. Al fi nalizar la activación del canal “out 2” el proceso fi naliza.
6. Para volver a iniciar el proceso vuelva a pulsar el botón “start/pause” (8).
7. FUNCIÓN PAUSA “ON”: Para pausar durante el funcionamiento pulse el botón “start/pause”
(8). El proceso se detendrá en ese momento dejando encendido el canal que estaba activado.
Vuelva a pulsar el botón “start/pause” (8) para reanudar el proceso.