EN-54
RANGER
®
7000 SCALES
5.12
Event Counter
For jurisdictions that use the audit trail sealing method, the local weights and measures official or authorized
service agent must record the current configuration and calibration event counter values at the time of sealing.
These values will be compared to values found during a future inspection.
Note:
A change to an event counter value is equivalent to breaking a physical seal.
The audit trail uses two event counters to record changes to configuration and calibration settings.
The configuration event counter (CFG) will index by 1 when exiting the menu if one or more of the following
menu settings are changed: Zero Range, Stable Range, Auto Zero Tracking (AZT), Units (kg, g, oz, lb or
lb:oz) or Stable Only.
The calibration event counter (CAL) will index by 1 when exiting the menu if a Span Calibration or GEO
setting change is made. Note that the counter only indexes once, even if several settings are changed.
5.13
Maintenance
Export
Library
Export User
Profile
Import
Library
Drives
Import User
Profile
Note:
The import/export is only functional when the current user is administrator.
Maintenance Sub-menu
5.13.1 Export Library
Export Library to USB flash drive.
5.13.2 Export User Profile
Export Export User Profile to USB flash drive.
.
5.13.3 Import
’ Library Drives
Import Library from USB flash drive.
5.13.4 Import User Profile
Import User Profile from USB flash drive.
Note: