EN 24                                                                                             Ranger

 4000 Count Series    

5. LEGAL FOR TRADE 

When the scale is used in trade or a legally controlled application it must be set up, verified and 
sealed in accordance with local weights and measures regulations. It is the responsibility of the 
purchaser to ensure that all pertinent legal requirements are met. 

5.1 Capacity Label 

A label showing the capacity and readability of the scale must be installed near each display. If 
the Capacity Labels were installed prior to delivery, no further action is needed. If the Capacity 
Labels  were  not  installed,  they  have  been  placed  in  the  packaging  material.  Affix  the  labels 
above the displays as shown in Figure 5-1. 

Note:

 The Capacity Labels will be destroyed upon removal, so only attempt to install them once. 

 

 

Figure 5-1. Capacity Label location 

 
 
 

5.2 Settings

 

Before verification and sealing, perform the following steps: 
1. Verify that the menu settings meet the local weights and measures regulations. 
2. Perform a calibration as explained in Section 3.9. 
3. Set the switch to Locked. See figure 5-1. 
 
The  Menu  Lock  switch  limits  changes  to  the  Cal,  Setup,  Readout,  Unit  and  Print  menus.  The 
switch  in  type  approved  models  may  set  some  scale  settings  as  required  by  the  approval 
agency. The switch may be secured using paper seals, wire seals or plastic ties.  
 

Note:

  When  LEGAL  FOR  TRADE  is  set  to  ON  (LFT  Switch  in  locked  position),  the  menu 

settings are affected as follows: 

 

Calibration (

C.A.L

) menu is not accessible 

 

Dual Scale, Capacity 2, Graduation 2 and Units are locked at their current settings 

 

Zero Range setting is locked at 2% 

 

Stable Range setting is locked at 1d 

 

Auto-Zero Tracking setting is locked at 0.5d 

 

Stable Only is locked On 

 

Auto Print/ Continuous is disabled 

 

Lb:oz is locked Offf 

 

5.2 Verification and Sealing 

The local weights and measures official or authorized service agent must perform the 
verification procedure. 
 

5.3.1 Physical Seals

 

For jurisdictions that use the physical sealing method, the local weights and measures official or 
authorized service agent must apply a security seal to prevent tampering with the settings. 
Refer to the illustration below for sealing methods. 
 
 

Capacity Label

 

Summary of Contents for RC41M15-M

Page 1: ...Ranger 4000 Count Series Instruction Manual Manual_RC41_V1...

Page 2: ......

Page 3: ...azard Alternating Current 1 2 Safety Precautions Please follow these safety precautions Verify that the AC input voltage printed on the data label matches the local AC power supply Only connect the po...

Page 4: ...al pan 2 3 Selecting the Location Use the scale on a firm steady surface Avoid locations with excessive air current vibrations heat sources or rapid temperature changes Allow sufficient space around t...

Page 5: ...eration the battery symbol indicates the battery charge level The scale will automatically turn off when the batteries are fully discharged For maximum operating time the battery should be charged at...

Page 6: ...s2 Off Turn scale off Units Change the weighing unit Switch between Check Weigh Check Count and Off Menu Enter user menu View the Audit Trail event counters extended press Menu Function Short Press Ye...

Page 7: ...ss and hold for more than 2 seconds TABLE 3 2 LCD Symbols Item Description Item Description 1 NET symbol 10 Low Sample Weight Symbol 2 Center of Zero symbol 11 Auto Optimization Symbol 3 Negative symb...

Page 8: ...active weighing mode To turn the scale off press and hold the On Zero Off button until OFF is displayed 3 3 Counting Ranger Count 4000 has three display areas Weight Piece Weight and Count informatio...

Page 9: ...teger 5 Press the Sample key will be displayed in both the piece window and the count window 6 The established APW and count will be displayed Entering a known APW 1 Press the APW key will be displaye...

Page 10: ...on the pan or in the container If the sample weight is under the target weight range the yellow LED will light If the sample is within the target weight range the green LED will light If the sample is...

Page 11: ...ly a different ID number may be selected using the keypad and then pressing the ID key Note Maximum 30 records from 0 to 29 Retrieving a record 1 Enter the ID number using the keypad and press the ID...

Page 12: ...nter the ID number using the keypad and press the ID key reCall and lib are displayed in the weight and piece weight windows respectively 2 Press the C key delete is displayed in the weight window Pre...

Page 13: ...o On Some units may not be available in all models When LEGAL FOR TRADE is set to ON LFT Switch in locked position the menu settings are affected as follows Calibration C A L menu is not accessible Du...

Page 14: ...te weighing results Before performing the calibration be sure to have the appropriate calibration weights as listed in table 4 1 Ensure that the LFT switch calibration lock is set to unlocked position...

Page 15: ...m 0 to 31 are available with 12 being the default Refer to table 4 2 to determine the GEO factor that corresponds to your location End Cal End Advance to the next menu or return to the top of the curr...

Page 16: ...f kg kilograms g grams lb pounds oz ounces lb oz pound ounces Zero Range ZErO Set the percentage of scale capacity that may be zeroed 2 zero up to 2 percent of capacity 10 zero up to 10 percent of cap...

Page 17: ...utton is pressed OFF no sound ON sound Accumulation aCCUmM Set the accumulation functionality OFF accumulation disabled AUTO automatic accumulation MAN manual accumulation End Setup End Advance to the...

Page 18: ...anges Auto off A OFF Set the automatic shut off functionality OFF disabled 1 powers off after 1 minute of no activity 5 powers off after 5 minute of no activity 10 powers off after 10 minute of no act...

Page 19: ...time the stability criteria are met INTER printing occurs at the defined interval ACCEPT printing occurs continuously CONT printing occurs each time the display is within the Checkweigh accept range a...

Page 20: ...nted Info Set the status OFF disabled ON the reference information is printed APW Set the status OFF disabled ON enabled Accu Set the status OFF disabled RESULT the Accumulation result is printed ALL...

Page 21: ...l Notes For Windows 7 setup contact Ohaus If the weighing value is a negative number set the target cell in TEXT format Otherwise Excel will not distinguish it as a negative number Please do not use t...

Page 22: ...ng ON OFF XON XOFF software handshaking Alternate command Alt CmM Define command character for the Print Tare and Zero commands Print Set the alternate command character for Print A to Z Tare Set the...

Page 23: ...et the status OFF COM menu is not locked ON COM menu is locked End Lock End Advance to the next menu or return to the top of the current menu 4 9 End Menu Press Yes to advance to the Calibration menu...

Page 24: ...EN 22 Ranger 4000 Count Series Figure 4 1 Setup for the Weigh Below Hook Weigh Below Hook Access...

Page 25: ...2 11 42 19 43 26 17 16 16 15 15 14 14 13 13 12 12 43 26 44 32 17 17 16 16 15 15 14 14 13 13 12 44 32 45 38 18 17 17 16 16 15 15 14 14 13 13 45 38 46 45 18 18 17 17 16 16 15 15 14 14 13 46 45 47 51 19...

Page 26: ...s explained in Section 3 9 3 Set the switch to Locked See figure 5 1 The Menu Lock switch limits changes to the Cal Setup Readout Unit and Print menus The switch in type approved models may set some s...

Page 27: ...Ranger 4000 Count Series EN 25 Figure 5 1 Sealing Unlocked Locked with Paper Seal Locked with Wire Seal Paper Seal Wire Seal Lock Switch...

Page 28: ...wer On Error Weight reading below Power On Zero limit Err 8 3 Over Range Error Weight reading exceeds Overload limit Err 8 4 Under Range Error Weight reading below Underload limit Err 8 5 Tare out of...

Page 29: ...0 lb x 0 001 lb 480 ox x 0 02 oz 30 kg x 0 001 kg 30000 g x 1 g 60 lb x 0 002 lb 960 oz x 0 04 oz Maximum Displayed Resolution 1 30000 Minimum Recommended Sample Weight 2g 0 004lb 4g 0 01lb 10g 0 02lb...

Page 30: ...r unstable CP Continuous Print SP Print on Stability xS 0S Turn off Stable Only menu item and allow unstable print 1S Turn on Stable Only menu item and only print stable print xP Interval Print x Prin...

Page 31: ...he pin connections are as follows Active pins PIN 2 TXD PIN 3 RXD PIN 5 Ground Figure 7 2 RS232 Pins 7 4 Printouts The following sample print outs are generated by the Print button P Command or altern...

Page 32: ...iate left of most significant character if negative Unit Up to 5 characters left justified If the Unit in the Print Content menu was set to OFF the unit will be removed in the weight string and replac...

Page 33: ...turers work It comprises all tests according to the adopted European standard EN 45501 1992 paragraph 8 2 2 If national regulations limit the validity period of the verification the user of the weighi...

Page 34: ...e has been designed for safe removal of the batteries at end of life by a waste treatment facility Please dispose of this product in accordance with local regulations at the collecting point specified...

Page 35: ...has been damaged by accident or misuse exposed to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modification by other th...

Page 36: ...edor del mundo Avec des bureaux dans le monde entier Weltweite Gesh ftsstellen Con uffici in tutto il mondo www ohaus com 30037454 P N 30037454A 2015 OHAUS Corporation all rights reserved todos los de...

Reviews: