EN-14                                                                         Valor™ 2000W Series

 

 

6.1 Specifications

 

TABLE 6-1 

MODEL** 

V22PWE1501T 

V22XWE1501T 

V22PWE3T 

V22XWE3T 

V22PWE6T 

V22XWE6T 

V22PWE15T 

V22XWE15T 

V22PWE30T 

V22XWE30T 

Capacity x Readability (Max x d) 

1.5 kg x 0.0002 kg 

1500 g x 0.2 g 

3 lb x 0.0005 lb 

48 oz x 0.01 oz 

3 kg x 0.0005 kg 

3000 g x 0.5 g 

6 lb x 0.001 lb 

96 oz x 0.02 oz 

6 kg x 0.001 kg 

6000 g x 1 g 

15 lb x 0.002 lb 

240 oz x 0.05 oz 

15 kg x 0.002 kg 

15000 g x 2 g 

30 lb x 0.005 lb 

480 oz x 0.1 oz 

30 kg x 0.005 kg 

30000 g x 5 g 

60 lb x 0.01 lb 

960 oz x 0.2 oz 

Maximum Displayed Resolution 

7500 

6000 

6000 

7500 

6000 

Repeatability (at 20°C) 

0.2 g 

0.5 g 

1 g 

2 g 

5 g 

Linearity (at 20°C) 

±0.2 g 

±0.5 g 

±1 g 

±2 g 

±5 g 

Weighing Units 

g, kg, lb, oz, lb:oz * 

Tare Range 

To capacity by subtraction 

Stabilization Time 

 0.5 seconds 

Safe Overload Protection 

150 % of scale capacity 

Weight Display  

2 x Red LED (front and rear) 

6-digit 7-segment, 20.5 mm / 0.8 in characters 

Keyboard 

V22PW: 2 buttons, V22XW: 4 buttons 

Application Modes 

V22PW: Weighing, V22XW: Weighing, Checkweighing 

Battery Operating Time (at 

20ºC) 

Typically 50 hours with 12-hour full charge 

Construction 

V22PW: ABS housing with 304 stainless steel platform 

V22XW: ABS bottom housing with 304 stainless steel top housing and platform 

Ingress Protection 

IPX8 

Pan Dimensions 

190 x 242 mm / 7.5 x 9.5 in 

Net Weight 

V22PW: 3.0 kg / 6.6 lb 

V22XW: 3.9 kg / 8.6 lb  

Shipping Weight 

V22PW: 4.0 kg / 8.8 lb 

V22XW: 4.9 kg / 10.8 lb  

Shipping Dimensions 

410 x 370 x 220 mm / 16.1 x 14.6 x 8.7 in 

Note: *  

For V22PW, see section 3.5. 

 **

Models without “T” (e.g. V22PWE3) are single display versions. These are only available in 

  

certain 

countries.

 

6.2 Drawings and Dimensions

 

                                                                                                                    TABLE 6-2 

 

 

V22PW 

V22XW 

A 256 mm  

10.1 in 

256 mm 

10.1 in 

B 280 mm  

 11 in 

288 mm  

 11.3 in 

C 121 mm  

 4.8 in 

124 mm  

 4.9 in 

A

 

B

C

Figure 6-1. Dimensions

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

Summary of Contents for Valor 2000W Series

Page 1: ...ie Valor 2000W Manual de instrucciones S rie Valor 2000W Manuel d instructions Valor 2000W Serie Bedienungsanleitung Serie Valor 2000W Manuale di istruzioni www GlobalTestSupply com Find Quality Produ...

Page 2: ...conditions specified in these instructions Service should be performed only by authorized personnel Only use weights within the scale s capacity as specified in these instructions Do not operate the s...

Page 3: ...2 Level Indicator 2 5 Power The AC Adapter is used to power the scale when battery power is not needed First connect the AC Adapter plug to the scale input jack located at the bottom of the scale acco...

Page 4: ...battery operation the battery symbol indicates the battery charging status When charging the symbol will blink slowly and when fully charged the symbol will stop blinking TABLE 2 1 Symbol Charge Level...

Page 5: ...ting Short Press Enter clear a Tare value Extended Press3 Initiates Calibration procedure Short Press in Menu Toggles through available settings Notes 1 Short Press Press less than 2 5 seconds 2 Long...

Page 6: ...s displayed 3 3 Calibration Menu To enter the calibration menu extend press Cal button for 5 seconds SpaN will then be displayed Press Zero key to perform span calibration or press Cal key to proceed...

Page 7: ...ow instructions to enter the service menu to set the displayed unit With the scale off and LFT off extend press both the On Zero and Tare keys at the same time for more than 8 seconds until rAmMP is d...

Page 8: ...oggles through active Units Short Press in Menu Toggles through available settings Short Press Initiates an application mode specific response Long Press Selects active Mode Short Press in Menu return...

Page 9: ...nstalled it should be calibrated to ensure accurate results Before performing the calibration be sure to have the appropriate calibration weights as listed in table 3 3 Press and hold Menu until mMeNU...

Page 10: ...the Low limit value Press Yes to accept or No to edit the Low limit value The stored value then displays with the first digit highlighted 000 000 kg Repeatedly press No until the desired number appear...

Page 11: ...cates factory default setting Note The Calibration Menu Mode indicator is displayed when in the Menu Mode 4 6 2 Cal Menu Enter this menu to perform calibrations Span SpaN yes no Initiates a span calib...

Page 12: ...40 05 15 15 14 14 13 13 12 12 11 11 10 40 05 41 12 16 15 15 14 14 13 13 12 12 11 11 41 12 42 19 16 16 15 15 14 14 13 13 12 12 11 42 19 43 26 17 16 16 15 15 14 14 13 13 12 12 43 26 44 32 17 17 16 16 15...

Page 13: ...rtment 5 Remove the plastic pan 6 Clean the plastic pan 6 3 1 2 4 5 Figure 5 1 Pan cleaning 5 2 2 Reinstalling the pan after cleaning Please follow the steps below to reinstall the plastic pan see als...

Page 14: ...of range Tare value exceeds maximum Err 9 Data Internal data error Contact an authorized service agent Err13 mMEmM Fail to write EEPROM Contact an authorized service agent Err 53 C SUmM Invalid checks...

Page 15: ...lay 2 x Red LED front and rear 6 digit 7 segment 20 5 mm 0 8 in characters Keyboard V22PW 2 buttons V22XW 4 buttons Application Modes V22PW Weighing V22XW Weighing Checkweighing Battery Operating Time...

Page 16: ...irective 2006 66 EC introduces new requirements from September 2008 on removability of batteries from waste equipment in EU Member States To comply with this Directive this device has been designed fo...

Page 17: ...standard s requirements On June 21 2012 OHAUS Corporation USA was re registered to the ISO 9001 2008 standard Limited Warranty OHAUS products are warranted against defects in materials and workmanship...

Reviews: