19
Differential weighing stores tare and weight values so a sample can be dried and the difference calculated at a later
time. Up to 100 samples can be stored. samples can be added to the applications library. Batch and individual
samples can be accommodated.The features in the Voyager balance for differential weighing include:
RECALL
- When selected, brings up previously stored library names associated with each sample.
LIBRARY NAME
- A name up to 10 characters can be entered and stored to identify the sample item.
TARE WEIGHT
- This is the tare weight of the container holding the samples, can be set to NO or YES.
AUTO TARE
- Used when it is desired to automatically tare the storing container's weight, can be set to NO or YES.
AUTO SAMPLE DETECT
- This feature is used for repetitive sample weighing, can be set NO or YES.
MODE
- Can be set to INDIVIDUAL or BATCH.
FINAL RESULT
- Can be set to show results in PERCENTAGE or WEIGHT.
SAMPLE NUMBERS
- Desired number of samples can be entered.
SAVE TO LIBRARY
- Permits all entries to be saved to the Library.
EXIT TO WEIGH
- When selected, will exit to standard weighing mode.
3.10
Differential Weighing
Go Back
Help
Enter
or
Go Back
Help
Enter
DIFF WEIGHING -- NAME-- SAMPLE 1
0%
100%
GRAMS
STABLE
EDIT
MAIN
CONTRAST
ENTER
0.00
INIT WT=
0.00
TARE WT=
0.00
WEIGHT
0%
100%
GRAMS
STABLE
MOVE HIGHLIGHT
MAIN MENU
CONTRAST
Procedure
• Press
arrow button to select MAIN MENU.
• Press
Enter
button.
• Using the arrow buttons, select CHANGE MODE.
• Press
Enter
button.
• Press
or
arrow button and select DIFF-
WEIGHING.
• Press
Enter
button.
• Press
or
arrow button and select RECALL,
SETUP or EXIT TO WEIGH.
• Press
Enter
button. If RECALL was selected, you
can scan the library and select the desired item.
• If SETUP is selected, continue by pressing
Enter
button.
• On the SETUP MENU, using the arrow buttons and
Enter
button, select YES or NO for each of the
following items on the menu: TARE WEIGHT, AUTO
TARE, AUTO SAMPLE DETECT; for MODE, select
either INDIVIDUAL or BATCH; for FINAL RESULT,
select either WEIGHT or PERCENT; for SAMPLE
NUMBERS, enter the desired number of samples to
be weighed; enter a name for LIBRARY NAME; scroll
down using the arrow button and select SAVE TO
LIBRARY by pressing
Enter
button.
• Scroll to RUN, press
Enter
button. DIFF WEIGHING-
SAMPLE 1 is displayed as shown below.
MAIN MENU
CHANGE UNITSPART
S
ET BALANCE
RETURN TO
WEIGH
CALIBRATION
CUSTOM MENU
CHANGE MODE
CHANGE MODE
BASIC WEIGHING
PARTS COUNTING
FILLING
ANIMAL WEIGHING
CHECK WEIGHING
DIFF WEIGHING
FORMULATION
QUICK CHECK
STATISTICS
DENSITY
MAIN MENU
CHANGE UNITSPART
S
ET BALANCE
LIBRARY
CALIBRATION
CUSTOM MENU
CHANGE MODE
CHANGE MODE
BASIC WEIGHING
PARTS COUNTING
FILL
ANIMAL WEIGHING
CHECK WEIGHING
DIFF WEIGHING
FORMULATION
QUICK CHECK
STATISTICS
DENSITY
DIFF WEIGHING
SETUP
RECALL
RESUME
EXIT TO WEIGH
MAIN MENU
CHANGE UNITSPART
S
ET BALANCE
RETURN TO
WEIGH
CALIBRATION
CUSTOM MENU
CHANGE MODE
CHANGE MODE
BASIC WEIGHING
PARTS COUNTING
FILL
ANIMAL WEIGHING
CHECK WEIGHING
DIFF WEIGHING
FORMULATION
QUICK CHECK
STATISTICS
DENSITY
DIFF WEIGHING
SETUP
RECALL
RESUME
EXIT TO WEIGH
MAIN MENU
CHANGE UNITSPART
S
ET BALANCE
RETURN TO
WEIGH
CALIBRATION
CUSTOM MENU
CHANGE MODE
CHANGE MODE
BASIC WEIGHING
PARTS COUNTING
FILL
ANIMAL WEIGHING
CHECK WEIGHING
DIFFERENTIAL WEIGHING
FORMULATE
QUICK CHECK
STATISTIC
DENSITY
DIFF WEIGHING
S
RECALL
RS
ETUP
EXIT TO WEIGH
SETUP
TARE WEIGHT NO
AUTO TARE NO
AUTO SAMPLE DETECT NO
MODE INDIVIDUAL
FINAL RESULT WEIGHT
SAMPLE NUMBERS 3
LIBRARY NAME NAME
SAVE TO LIBRARY
Summary of Contents for Voyager V10640
Page 61: ...55...
Page 62: ...56...
Page 65: ...1 Ohaus Corporation 29 Hanover Road Florham Park NJ 07932 0900 Operating instructions balances...
Page 154: ...Operating instructions balances O T O T O T O T OHAUS...
Page 243: ......
Page 245: ......