■メンテナンス

/Maintenance 

1

3

ヶ月に

1

回電極の点検を行い、汚れている場合には洗浄を行ってください。

 

  Check the electrodes every month or at least quarterly basis and carry out cleaning if they are dirty. 

・アラームメッセージ表示(

E1

E2

E3

E6

)したときに電極の洗浄、碍子の清掃を行ってください。

 

    Clean the electrodes and the insulators on the occurrence of E1, E2, E3 or E6 alarm. 

注意

/

Caution

 

 

 
 

 

 

メンテナンス作業を行う場合は、必ず

STOP

を押し電源の供給を停止し、ファンが停止したことを確認

 

して作業を行ってください。→けが、破損の原因になります。

 

Before starting any maintenance work, be sure to press STOP button to disconnect power and 
make sure that the fan has stopped completely.   

 Failure to this can be a cause of injury or breakage of the product.

 

 

電源の供給停止後、放電させるために

30

秒以上放置してから作業を行ってください。

 

→感電の原因になります。

 

For prevention of electrical shock, let MISTCATCH discharge static electricity for at least 30 seconds 
after power shutdown and then carry out maintenance work. 

メンテナンスをする際には手袋などをして、ケガを防止してください。

 

Put on groves to protect your hands. 

モータのフレームは高温になりますので、素手でさわらないでください。

 

Motor frame can be very hot. Do not touch it with bare hands. 

電極洗浄後は電極を完全に乾燥させて水気を無くしてから取付けてください。→故障の原因になります。

 

Dry the electrodes completely cleaning and then remount. Remaining moisture on electrodes can be a 
cause of breakdown. 

電極を洗浄するための洗浄液は中性または弱アルカリ性のものをご使用ください。

 

Use neutral or weak alkaline detergent for washing the electrodes. 

電源ケーブルを無理に引っ張ったり、曲げたり、はさみ込んだりしないでください。

 

Do not tug, bend or pinch the power cable during the work. 

 

電極を取出す際は、しっかり持って落とさないようにしてください。

 

→けが、破損の原因になります。

 

When taking out an electrode, hold it firmly to avoid accidental dropping. 

 Failure to this can be a cause of injury or breakage of the product. 

   

●電極の洗浄方法

/

Cleaning of Electrode 

①操作パネルのSTOPボタンを押し、電源の供給を停止します。

 

30

秒以上放置した後、モータの回転が停止していることを確認してください。

 

Press STOP button on the operation panel to disconnect power. 

Wait at least 30 seconds and make sure that the motor has stopped completely. 

 

②六角ボルトを緩め、電極取出し扉を開けてください。

 

    Loosen the hexagon head bolts to open the Electrode access door. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Hexagon head bolt 

六角ボルト

 

Summary of Contents for MIST CATCH OMC-E325

Page 1: ...ference This brochure contains general instructions for safety handling installation operation and maintenance of MISTCATCH However please understand that they may not cover all possible contingencies...

Page 2: ...Contents Safety precautions Part names Installation Prior to operation Operation Warning Safeguard Maintenance Specifications Maintenance parts Warranty...

Page 3: ...designated under Fire Defense Law of Japan Please ensure that the following substances are not allowed to enter into MISTCATCH since it aims to inhale common oil mist generated from machinery in prod...

Page 4: ...ay from the rotating part of fan 1000m This product is not designed for using outdoor or at high altitude above 1000 meters The site of use should be free from stress such as vibrations or impacts Do...

Page 5: ...ollecting electrode Pre filter Drain pipe Lamp Electrode access door Operation panel Exhaust port Suction port Fan Exhaust port Electrode access door Suction port Drain pipe Lamp Operation panel Motor...

Page 6: ...the MISTCATCH right side up and fix it perpendicularly and horizontally within a tolerance of 2 Failure to this may lead to scattering of water due to poor drainage Where the suction port is close to...

Page 7: ...sonnel M10 M10 Fix the bottom of the MISTCATCH at 4 points with M10 bolts and nuts M10 bolts and nuts are not included in the supply Duct and drain works OMC E325 Intake piping for OMC E325 200 For OM...

Page 8: ...included in the supply When you fabricate an original duct flange like an example illustrated below secure it with 12 M8 bolts using the holes provided It is recommended to seal around the jointed par...

Page 9: ...il drainage If oil is pooled inside the hose scattering can occur 400mm When submerged keep at least 400mm distance between the drain port and the liquid surface Caution The suctioning duct should tak...

Page 10: ...er s action is not interrupted by other equipment Do not connect an inverter to the power source Failure to this may lead to breakdown of the product M4 4 Detach the cover for the electrical connectio...

Page 11: ...for external operation input is wrong external operation is disabled Tighten the dome nut of the cable gland to fix the cable OMC E345 For wiring of OMC E345 secure the cable using a cable tie as ill...

Page 12: ...se it rotates to the opposite direction exchange R and S of the power supply ALARM ALARM lamp Red Display Lights up when current is applied POWER POWER lamp Opaque white Lights up or blinks in the eve...

Page 13: ...setting F1 Initial setting 8 Setting range 7 8 or 9 This is to change over high voltage output level According to the output value to each electrode collection amount of oil mist and maintenance inter...

Page 14: ...arm Alarm 2 output setting F3 Initial setting 0 Setting range 0 1 This is to set whether to output maintenance reminder 0 Alarm indication and contact output are ineffective 1 Alarm indication and con...

Page 15: ...r safety reasons in case a large amount of spark or short circuit has occurred at charge electrode or collecting electrode If it is desired not to stop mist emission set it to 1 for continuous operati...

Page 16: ...In 5 seconds after starting operation high voltage is applied to the electrodes and mist collection starts During operation voltage current and cumulative operation time are displayed by turns as wel...

Page 17: ...dirt in the electrodes the alarm lamp red lights up At the same time high voltage output and motor operation will stop and the alarm output contact 1 will close Display shows E2 only Clean the electr...

Page 18: ...contact 2 will close Display shows E5 Turn power off immediately and contact the supplier E6 1 E6 SET 3 E6 Alert for overcurrent between electrodes In case overcurrent is generated between the electr...

Page 19: ...and then carry out maintenance work Put on groves to protect your hands Motor frame can be very hot Do not touch it with bare hands Dry the electrodes completely cleaning and then remount Remaining mo...

Page 20: ...electrodes with a brush Dry the electrodes completely after washing Caution Operating a MISTCATCH with wet electrodes can be a cause of sparking Caution Before attaching each electrode make sure that...

Page 21: ...detach a Needle electrode unit from the spring For fixing it again first attach the Needle electrode unit to the spring and then fit the hook After fitting check that all the Needle electrode units a...

Page 22: ...open the electrode access door to take out the pre filter Soak the pre filter in cleaning liquid to remove dirt In case the filter is clogged with machining swarf or oil blow them off by compressed a...

Page 23: ...dirty electrode P19 Clean the electrodes See page 19 Oil mists generated are beyond the ability of the product Contact the supplier In case any trouble occurred during operation turn off power immedi...

Page 24: ...WER OPERATION ALARM POWER lamp Opaque white OPERATION lamp Orange ALARM lamp Red External operation input DC24V 24VDC Continuous signal External output 1a AC250V 2A DC30V 2A 2 Alarm output 1a AC250V 2...

Page 25: ...Complete set of supply Main unit 1 32 2 Drain hose 2m 1 Drain hose band 1 Instruction manual 1 Outline drawing OMC E325...

Page 26: ...OMC E345 Outline of electrode Charge electrode Weight approx 3 6kg Collecting electrode Weight approx 12 8kg...

Page 27: ...gent K79 Aluminum safe cleaning agent OMC E325 Motor of OMC E325 OMC N210 M75 OMC E345 Motor of OMC 345 OMC N215 M150 Closing plate for suction port OMC E047 1 Warranty 1 This product is covered with...

Page 28: ...21 Main Factory 7000 21 Nakagawa Hosoe Kita ku Hamamatsu Shizuoka 431 1304 Japan TEL 81 53 522 5562 FAX 81 53 523 2362 http www ohm jp e index html 2 2019 10 2nd Edition The contents of this manual is...

Reviews: