③荷電極、捕集電極を取っ手を引いて取出してください。

 

       

注意電極を取出すときに、碍子を持たないでください。→破損の原因となります。

 

Pull the handle to take out the charge electrode and the collecting electrode. 
Caution Do not hold the insulators for taking out the electrodes as insulators are breakable. 

 
 
 
 

 

     
 
 
 
 

 
 
 
 

④電極を洗浄液に漬け置きして汚れを落としてください。

 

汚れが落ちにくい場合はブラシ等を使用して汚れを取除いてください。

 

超音波洗浄器や温水を使用すると汚れが落ち易くなります。

 

注意ブラシ等を使用する場合には針電極が変形しないように注意してください。

 

Soak the electrodes in cleaning liquid. Use a brush for removing tough stains.   
Use of an ultrasonic cleaner or hot water will make cleaning work easy. 

Caution Pay attention not to deform the needle electrodes with a brush. 

 
 
 
 

 
 

⑤水洗いした後、完全に水分を乾燥させてください。

 

注意水分が付いたまま運転するとスパーク発生原因になります。

 

       

注意電極を取り付ける前に、電極の変形、異物の付着等がないか確認してください。

 

Dry the electrodes completely after washing. 

Caution Operating a MISTCATCH with wet electrodes can be a cause of sparking. 
Caution Before attaching each electrode, make sure that it is not deformed and there is no adhesion of foreign 

matters to it. 

 

⑥電極を元通りに装置に取付けてください。

 

右図の向きで、電極を奥まで差し込んでください。

 

Put the electrodes back in place. 
Push them in to the depth in the direction as shown 
in the illustration. 

 

⑦電極取出し扉を閉めて六角ボルトを確実に締めてください。

 

Close the Electrode access door and fix   
the hexagon head bolts securely. 

 

推奨洗浄液

   

スーパーアルサット

K79 

メーカ:

(

)

サンワード

 

Use an aluminum safe cleaning agent 
of neutral or weak alkaline   

Handle 

取っ手

 

荷電極

 

Charge electrode 

取っ手

 

Handle

 

捕集電極

 

Collecting electrode 

Summary of Contents for MIST CATCH OMC-E325

Page 1: ...ference This brochure contains general instructions for safety handling installation operation and maintenance of MISTCATCH However please understand that they may not cover all possible contingencies...

Page 2: ...Contents Safety precautions Part names Installation Prior to operation Operation Warning Safeguard Maintenance Specifications Maintenance parts Warranty...

Page 3: ...designated under Fire Defense Law of Japan Please ensure that the following substances are not allowed to enter into MISTCATCH since it aims to inhale common oil mist generated from machinery in prod...

Page 4: ...ay from the rotating part of fan 1000m This product is not designed for using outdoor or at high altitude above 1000 meters The site of use should be free from stress such as vibrations or impacts Do...

Page 5: ...ollecting electrode Pre filter Drain pipe Lamp Electrode access door Operation panel Exhaust port Suction port Fan Exhaust port Electrode access door Suction port Drain pipe Lamp Operation panel Motor...

Page 6: ...the MISTCATCH right side up and fix it perpendicularly and horizontally within a tolerance of 2 Failure to this may lead to scattering of water due to poor drainage Where the suction port is close to...

Page 7: ...sonnel M10 M10 Fix the bottom of the MISTCATCH at 4 points with M10 bolts and nuts M10 bolts and nuts are not included in the supply Duct and drain works OMC E325 Intake piping for OMC E325 200 For OM...

Page 8: ...included in the supply When you fabricate an original duct flange like an example illustrated below secure it with 12 M8 bolts using the holes provided It is recommended to seal around the jointed par...

Page 9: ...il drainage If oil is pooled inside the hose scattering can occur 400mm When submerged keep at least 400mm distance between the drain port and the liquid surface Caution The suctioning duct should tak...

Page 10: ...er s action is not interrupted by other equipment Do not connect an inverter to the power source Failure to this may lead to breakdown of the product M4 4 Detach the cover for the electrical connectio...

Page 11: ...for external operation input is wrong external operation is disabled Tighten the dome nut of the cable gland to fix the cable OMC E345 For wiring of OMC E345 secure the cable using a cable tie as ill...

Page 12: ...se it rotates to the opposite direction exchange R and S of the power supply ALARM ALARM lamp Red Display Lights up when current is applied POWER POWER lamp Opaque white Lights up or blinks in the eve...

Page 13: ...setting F1 Initial setting 8 Setting range 7 8 or 9 This is to change over high voltage output level According to the output value to each electrode collection amount of oil mist and maintenance inter...

Page 14: ...arm Alarm 2 output setting F3 Initial setting 0 Setting range 0 1 This is to set whether to output maintenance reminder 0 Alarm indication and contact output are ineffective 1 Alarm indication and con...

Page 15: ...r safety reasons in case a large amount of spark or short circuit has occurred at charge electrode or collecting electrode If it is desired not to stop mist emission set it to 1 for continuous operati...

Page 16: ...In 5 seconds after starting operation high voltage is applied to the electrodes and mist collection starts During operation voltage current and cumulative operation time are displayed by turns as wel...

Page 17: ...dirt in the electrodes the alarm lamp red lights up At the same time high voltage output and motor operation will stop and the alarm output contact 1 will close Display shows E2 only Clean the electr...

Page 18: ...contact 2 will close Display shows E5 Turn power off immediately and contact the supplier E6 1 E6 SET 3 E6 Alert for overcurrent between electrodes In case overcurrent is generated between the electr...

Page 19: ...and then carry out maintenance work Put on groves to protect your hands Motor frame can be very hot Do not touch it with bare hands Dry the electrodes completely cleaning and then remount Remaining mo...

Page 20: ...electrodes with a brush Dry the electrodes completely after washing Caution Operating a MISTCATCH with wet electrodes can be a cause of sparking Caution Before attaching each electrode make sure that...

Page 21: ...detach a Needle electrode unit from the spring For fixing it again first attach the Needle electrode unit to the spring and then fit the hook After fitting check that all the Needle electrode units a...

Page 22: ...open the electrode access door to take out the pre filter Soak the pre filter in cleaning liquid to remove dirt In case the filter is clogged with machining swarf or oil blow them off by compressed a...

Page 23: ...dirty electrode P19 Clean the electrodes See page 19 Oil mists generated are beyond the ability of the product Contact the supplier In case any trouble occurred during operation turn off power immedi...

Page 24: ...WER OPERATION ALARM POWER lamp Opaque white OPERATION lamp Orange ALARM lamp Red External operation input DC24V 24VDC Continuous signal External output 1a AC250V 2A DC30V 2A 2 Alarm output 1a AC250V 2...

Page 25: ...Complete set of supply Main unit 1 32 2 Drain hose 2m 1 Drain hose band 1 Instruction manual 1 Outline drawing OMC E325...

Page 26: ...OMC E345 Outline of electrode Charge electrode Weight approx 3 6kg Collecting electrode Weight approx 12 8kg...

Page 27: ...gent K79 Aluminum safe cleaning agent OMC E325 Motor of OMC E325 OMC N210 M75 OMC E345 Motor of OMC 345 OMC N215 M150 Closing plate for suction port OMC E047 1 Warranty 1 This product is covered with...

Page 28: ...21 Main Factory 7000 21 Nakagawa Hosoe Kita ku Hamamatsu Shizuoka 431 1304 Japan TEL 81 53 522 5562 FAX 81 53 523 2362 http www ohm jp e index html 2 2019 10 2nd Edition The contents of this manual is...

Reviews: