Brush assembly
mounting screw
Brush assembly
Must not hit
Passage plate
Passage plate lock screw
–
15
–
7. Replacing Parts
7.1 Replacing the Brush
Turn off the power switch before performing check and
adjustment work.
If the tip of the brush has worn to such degree that the brush can no
longer brush away screws in an abnormal posture, replace it with a new
brush.
• Turn this machine power switch on, then off to position the brush as
shown at top-right and then remove the brush assembly. (Have the
brush assembly positioned to ease the work of removing the mounting
screw.)
• The brush assembly can be disassembled as shown at right.
• To reassemble the brush assembly, reverse the removal procedure.
• When the reassembly is completed, check to make sure that the front of
the plastic part of the brush won’t hit the passage plate when the brush
assembly operates. A ideally clearance of 0 is recommended.
• For adjustment instructions, see 5.4, “Brush Check and Adjustment.”
7.2 Replacing the Passage Plate
Turn off the power switch before performing check and
adjustment work.
When using screws of different nominal diameters, replace the passage
plates for both the rail assembly and the Escaper Unit.
• Remove the Passage plate lock screw and then remove the passage
plate.
• Keep the setscrew in a safe place.
• Install the passage plate in position with reference to the drafts on its
both sides.
• After the adjustment, the passage pate requires adjustment to meet the
kind of screw to use.
For adjustment instructions, see 5.5, “Passage Plate Check and
Adjustment.”
Parts number
:
NJ02005a #02
Brush bracket 1
Brush bracket 2
Brush
Hex socket head
machine screw
M2.6x10
Spring washer
M2.6
Washer
M2.6
Brush assembly exploded view
CAUTION
CAUTION