17
–
Symptom
Cause
Action
8-1
This machine won’t start when
the power switch is turned on
8-2
Screws won’t come flowing
• Power is not connected.
• Screws that have accumulated at the
unloading port have not been unloaded for a
certain period of time.
• The unloading lever has not been pressed
firmly.
• Too many screws have been put in the
Screw bin (overload protective circuit
tripped).
• Foreign matters (such as screws) have
entered the inside of this machine (overload
protective circuit tripped).
• AC adapter failure
• Screws having a larger nominal diameter
than specified have been loaded, or screws
of different nominal diameters were present.
• The supply of screws in the Screw bin has
used up.
• Check that AC adapter power connection.
• Manipulate the unloading lever to unload screws
from the unloading port.
• Press the unloading lever firmly until it hits the
stopper (LCD panel LED going out).
• Adjust the Timer setting control screw.
• Adujst amount of screws in the Screw bin.
• Remove the foreign matters.
• Contact your service agent or dealer.
• Use screws of the specified nominal diameter.
• Remove the screws of the different nominal
diameters.
• Correct the supply of screws in the Screw bin.
• Use of the NEJIKURA option is recommended.
8. Points to Check Before Requesting Repair Services
Turn the power switch off before troubleshooting this machine.
CAUTION