Curve point 4 ver. 4
When the servomotors drive to position for a set curve point, the display
shows “>” instead of “:”.
When the servomotors have reached their positions, “:” returns to the
display.
Servomotor settings can be modified only when each servomotor has
reached its position.
This operation can be interrupted by pressing
Esc
. The display returns to its initial
state.
Capacity, servomotor and frequency converter settings can be scrolled through using
the
Select -/+
buttons.
Curve point 5 ver. 4
Press
Enter
at the desired parameter.
Curve point 6 ver. 4
Change setting using the
Select -/+
buttons. Then servomotors drive to their new
position. During that time, the display shows “>” instead of “:”. Confirm the change by
pressing
Enter
or undo by pressing
Esc
. Then you return to the previous menu level.
The servomotor turning angle is 0–90° and setting accuracy 0.1°. The capacity and
frequency converter setting range is 0–100% and they can be set at 0.1 % accuracy.
Adjust at point 1:
54 (102)
M4263 2206EN