INTRODUCTION

The thermostat is an electronic PWM/PI thermostat for temperature 
control by means of an NTC sensor located either externally or 
internally within the thermostat.
The thermostat is for flush mounting in a wall socket. A baseplate 
for wall mounting is also available.

This thermostat can be used as a controller for electric room 
heating pursuant to EN 50559.

Fig. 1 - Content

•  Thermostat
•  Sensor

IMPORTANT SAFETY INSTRUCTIONS
Fig. 2 - Warnings

To avoid electric shock, disconnect the heating system 
power supply at the main panel before carrying out any 
work on this thermostat and associated components.

Installation must be carried out by qualified personnel in 
accordance with appropriate statutory regulations (where required 
by law).

Installation must comply with national and/or local electrical codes.

Cautions

This instruction must be observed, otherwise the liability 
of the manufacturer shall be voided.

Any changes or modifications made to this thermostat 

shall void the liability of the manufacturer.
Maximum product lifetime is achieved if the product is not turned 
off but set at the lowest possible set point / frost protection when 
heat is not required.

Instruction

English

Summary of Contents for MWD5-1999-UAC3

Page 1: ...MWD5 1999 UAC3 MWD5 1999 UAC3 English INSTRUCTIONS 67984 11 22 KJE 2022 OJ Electronics A S...

Page 2: ...2 2022 OJ Electronics A S ILLUSTRATIONS Pages 3 6 INTRODUCTION English 7...

Page 3: ...3 2022 OJ Electronics A S MWD5 1999 UAC3 BR1017A02 Fig 1 Fig 2 BR1017A01 BR1017A01 BR1017A02...

Page 4: ...4 2022 OJ Electronics A S MWD5 1999 UAC3 BR1017A03A 1 5m BR1017A03a Fig 3 1 2 4 3 25 BR1017A04D 7A05A L Fig 4 BR1017A04d...

Page 5: ...5 2022 OJ Electronics A S MWD5 1999 UAC3 BR1017A05A 6 5 3 4 2 1 N L BR1017A06 Fig 5 Fig 6 BR1017A05a BR1017A06...

Page 6: ...6 2022 OJ Electronics A S MWD5 1999 UAC3 1 2 3 4 4 BR1017A14 BR1017A07 Fig 7 Fig 8 BR1017A07 ON OFF 1 2 Manual Menu Auto BR1017A17a Fig 9...

Page 7: ...disconnect the heating system power supply at the main panel before carrying out any work on this thermostat and associated components Installation must be carried out by qualified personnel in accord...

Page 8: ...e terminal block for the floor sensor they must be restrained using cable ties It is strongly recommended that the cable and sensor are placed in a non conductive installation pipe embedded in the flo...

Page 9: ...er part of the thermostat then from the upper part of the thermostat Fig 5 Connections Connect the wires in accordance with the diagram The wires must be connected as follows Term 1 Neutral N Term 2 L...

Page 10: ...e first time the thermostat is connected push the power slide button to On I The Installer Wizard on the touchscreen will guide you through the set up of 1 Region 2 Language 3 Date 4 Time 5 Floor Type...

Page 11: ...y only be cleaned with a dry cloth APPROVALS AND STANDARDS Regulations OJ Electronics A S hereby declares that the product is in conformity with the following directives of the European Parliament LVD...

Page 12: ...e with local regulations for waste processing Recycling of obsolete appliances Equipment containing electrical components must not be disposed of along with domestic waste It must be separately collec...

Page 13: ...ontrol principle PWM PI Standby consumption 0 5 W Battery backup 5 years storage Battery life typical 5 years storage 10 years powered RF frequency band 2 4 GHz WIFI IEEE 802 11 b g n 2 4GHz Security...

Page 14: ...e n o Title 2014 30 EU EMC Directive DIRECTIVE 2014 30 EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February 2014 on the harmonization of the laws of the Member States relating to electromag...