background image

English

Type OCC3 / OCD3

U S E R   M A N U A L

57695 05/08 - (BJ)

Type: OCC3 / OCD3

Buttons

Display symbols

N

M

L

K

H

I

J

A:

B:

C:

D:

E:

F:

G:

Pin button
adjust of 
clock

On/off

Reset to 
factory 
setting

Adjustment
down

OK - 
accept

Adjustment 
up

Display

H:

I:

J:

K:

L:

M:

N:

Clock 
function

Manual 
mode

Time and
temperature

Day number

Heating on


Monitoring 
of switch-on
time

4-event symbol

1. Getting started

Introduction 
The thermostat is capable of switching on your heating system at pre determined times on different days of the week. It is possible to set 4 periods called
events each day with different temperatures. From factory a default schedule is programmed suitable for most installations. Unless you change these
settings the thermostat will operate to this default program.

Working with lower temperatures during times that the room is unoccupied will lower your energy costs without reducing the comfort. The thermostat has an
adaptive function that automatically changes the start time of a heating period so that the desired temperature is reached at the time that you set. After 3
days the adaptive function has learned when the heating must be switched on. 

The thermostat has a built-in temperature sensor and an externally temperature sensor. In this configuration the thermostat controls the temperature within
the room and use the externally temperature sensor as limit sensor avoiding too high or too low temperatures in the floor construction. 

The thermostat has a pin button marked R, allowing you to reset the thermostat to factory settings. These are listed at the end of this manual with space for
you to record your own weekly schedule.

The display is backlit when operating the buttons. The heating element is switched off when the light is on in the display.

The heating system can be switched off on the built-in interrupter. The Microprocessor taking care of the time will still be supplied with power whereby time
and day will be maintained. When the heating is required and the thermostat is switched on, it will continue the 4-event programme based on present time
and day.

Setting the thermostat into operation

1-7

Press the UP (

) or DOWN (

) buttons to

select the correct time and press OK button (

).

Then press the UP (

) or DOWN (

) button to

select the correct day and press OK (

) button. 

First time power is connected the clock and day will be flashing and must be set. If you need to
adjust the time of the thermostat at a later date, insert a pin into the hole 

for setting of time

and day. Adjustment must be made for summer and winter time.

Wake

Night

Out

Home

1

Summary of Contents for OCC3

Page 1: ...mperature sensor and an externally temperature sensor In this configuration the thermostat controls the temperature within the room and use the externally temperature sensor as limit sensor avoiding t...

Page 2: ...he override temperature is set The unit will now operate to this temperature permanently Cancel manual mode To cancel the permanent override state press the OK button once and the unit will resume aut...

Page 3: ...ver to fall below the minimum set temperature Time and temperature scale selection Maximum allowed temperature setting Use the UP or DOWN button to increase or reduce and OK button to accept Next is d...

Page 4: ...www oj dk Adaptive function This function enables the thermostat to calculate when it needs to switch ON so that the required temperature is reached at the set time With a start time of 07 00 therefor...

Page 5: ...at heeft een ingebouwde n een externe temperatuursensor In deze configuratie regelt de thermostaat de temperatuur in de kamer en gebruikt de externe temperatuursensor als een limietsensor om te hoge o...

Page 6: ...NEER totdat de ophef temperatuur is ingesteld De unit zal nu onafgebroken op deze temperatuur werken Handbedieningstand annuleren Druk n keer op OK om de permanente ophef stand te annuleren De unit za...

Page 7: ...als het gewenst is dat de vloertemperatuur niet onder de minimum ingestelde temperatuur daalt Tijd en temperatuurschaal selecteren Maximum toegestane temperatuurinstelling Gebruik OP of NEER om te ve...

Page 8: ...k www oj dk Aanpasfunctie Met deze functie kan de thermostaat berekenen wanneer hij op AAN moet inschakelen zodat de gewenste temperatuur op de ingestelde tijd bereikt is De thermostaat moet bij een s...

Reviews: