background image

2. Daily use of the thermostat 
4-event clock mode
The day has been split into 4 events describing a typical day. When the thermostat is in 4-event mode it will automatically adjust the temperature according
to the required temperature to the required time. As standard the thermostat has 5 days with 4 events, and 2 days with 2 events. Programming see 3.

4-event clock mode:

Comfort mode:

Manual mode:

Temporary override
To temporarily override the temperature in the 4-event schedule program, press the UP (

) or DOWN (

) button

once, to show the temperature, and press again to increase or decrease the temperature. The display will flash for
5 seconds, and will then revert to the time. The override will operate until the next programmed event when the
unit will resume the automatic programme. 

The clock function symbol (

) and one of the 4-event symbols (

) will be indicated. 

Programming see 3.

Cancel comfort mode
To cancel the override state, press the OK ( ) button twice. 

Permanent override: 
During holidays, the scheduled 4-event program can be overridden. 
Press the OK (

) button, and then the UP ( ) or DOWN ( ) button until the override temperature is set. 

The unit will now operate to this temperature permanently. 

Cancel manual mode
To cancel the permanent override state press the OK ( ) button once, and the unit will resume automatic function. 

5 secs.

5 secs.

Press OK ( ) button for 3 secs. to begin programming

: Time and temperature

: Time and temperature

: Time and temperature

: Time and temperature

Day 1 - 5

Day 6 - 7

: Time and temperature

: Time and temperature

3. Programming
4-event time and temperature

For each event, the start time and required
temperature must be set. 

For example, in the morning you wish the heating to
start at 07:00 and the temperature to rise to 21˚C.
Press OK (

) button for 3 seconds and the start time

is displayed. Change this to 07:00 with the 
UP ( ) or DOWN ( ) button. Press OK  (

) to confirm. 

The temperature is now displayed. Change this to 21˚C
with the UP (

) or DOWN ( ) button. 

Press OK ( ) button to confirm. This action can now 
be repeated for the second event. 

These settings will be valid with days 1-5 showing on
the display. To program the days 6 and 7, repeat the
above. Days 6 and 7 are usually Saturday and Sunday,
and only have two events. 

The temperature can be set within the range of +5 to
+40˚C. It is also possible to select the heating OFF at
that event by reducing the setting to 5˚C, and then
pressing the ( ) once more. 

2

Summary of Contents for OCC3

Page 1: ...mperature sensor and an externally temperature sensor In this configuration the thermostat controls the temperature within the room and use the externally temperature sensor as limit sensor avoiding t...

Page 2: ...he override temperature is set The unit will now operate to this temperature permanently Cancel manual mode To cancel the permanent override state press the OK button once and the unit will resume aut...

Page 3: ...ver to fall below the minimum set temperature Time and temperature scale selection Maximum allowed temperature setting Use the UP or DOWN button to increase or reduce and OK button to accept Next is d...

Page 4: ...www oj dk Adaptive function This function enables the thermostat to calculate when it needs to switch ON so that the required temperature is reached at the set time With a start time of 07 00 therefor...

Page 5: ...at heeft een ingebouwde n een externe temperatuursensor In deze configuratie regelt de thermostaat de temperatuur in de kamer en gebruikt de externe temperatuursensor als een limietsensor om te hoge o...

Page 6: ...NEER totdat de ophef temperatuur is ingesteld De unit zal nu onafgebroken op deze temperatuur werken Handbedieningstand annuleren Druk n keer op OK om de permanente ophef stand te annuleren De unit za...

Page 7: ...als het gewenst is dat de vloertemperatuur niet onder de minimum ingestelde temperatuur daalt Tijd en temperatuurschaal selecteren Maximum toegestane temperatuurinstelling Gebruik OP of NEER om te ve...

Page 8: ...k www oj dk Aanpasfunctie Met deze functie kan de thermostaat berekenen wanneer hij op AAN moet inschakelen zodat de gewenste temperatuur op de ingestelde tijd bereikt is De thermostaat moet bij een s...

Reviews: