Press the pin button for 3 secs. and the thermostat returns to factory settings. Time
and day is also reset and must be set according to “Setting the thermostat into
operation”.
Note that a OCD3 that has been modified to a OCC3 (see 4. Advanced settings
and read-out, selection of type) will return to a OCD3. Failure code E2 will be
displayed if the external sensor has been removed.
5. Reset to factory setting
6. Failure codes
E0 =
Internal failure, replace thermostat
E1 =
Built-in sensor short-circuit or disconnected, replace thermostat
E2 =
External sensor short-circuit or disconnected
OJ ELECTRONICS A/S
Stenager 13B · DK-6400 Sønderborg
Tel. +45 73 12 13 14 · Fax +45 73 12 13 13
oj@oj.dk · www.oj.dk
Adaptive function:
This function enables the thermostat to calculate when it needs to switch ON so that the required temperature is reached at the set
time. With a start time of 07:00 therefore, the thermostat may switch ON as early as 06:00 so that the desired temperature of 25˚C is
achieved by 07:00. Without this function set, the thermostat will start to heat at the time you set.
}
☞
☞
☞
Press the DOWN ( ) button to switch between on and off.
Press OK ( ) button to confirm.
Press OK ( ) button to end programming and to return to
scheduled programme.
☞
☞
4
4-event time and temperature
Day 1-5
06:00
Time
Temperature
OCC3-1991
OCC3-1999
OCD3-1999
08:00
16:00
22:30
08:00
23:00
Hi-Low temp.
5:2
24 H / ˚C
ON
4-event sequence
Scale
Adaptive control
Day 6-7
25˚C
20˚C
20˚C
15˚C
15˚C
22˚C
22˚C
15˚C
15˚C
22˚C
22˚C
15˚C
15˚C
55˚C/5˚C 28˚C/15˚C
20˚C
27˚C
20˚C
27˚C
20˚C
55˚C/5˚C
Factory settings