Select the required 4-event schedule and confirm with
OK
.
For instructions on programming the time and temperature for the
4-event schedule, see
4-event settings
.
Energy monitor
Allows you to view energy consumption for
the past 2 days, 30 days or 365 days.
Press
OK
for the chosen period. The value
in per cent (%) shows the relative amount of
time the heating has been on. The following figure is the cost for the
selected period. To ensure correct calculation, check the settings for
currency, price per kWh and load.
Currency: Press
OK
and chose the required currency.
Confirm with
OK
.
Cost/unit: Press
OK
and set the actual cost of electricity.
The cost must be entered per kWh. Press
OK
.
Load:
Press
OK
and enter the connected heating power.
The value must be in watt (W). Press
OK
.
Leave the menu by pressing
Exit
.
Engineer settings
The Engineer settings menu contains the following options:
• Offset temperature
• Adaptive function
• Application
• Temperature scale
• Language
• Factory reset
• Information
Offset temperature
If the actual measured temperature does not
corresponding to the thermostat value, you
can adjust the thermostat by offsetting the
temperature.
Press
OK
and enter the value of the measu-
red temperature. Confirm with
OK
.
Adaptive function
Ensures that the required temperature has
already been reached when you get up in the
morning or come home from work. After just
a few days, the adaptive function will have
automatically calculated when the heating must be turned on.
Press
OK
and set the function to
On
. Confirm with
OK
.
Application
Set the type of regulation used.
There are 3 options:
Floor reg. :
The thermostat regulates floor
temperature only. A floor sen-
sor must be connected.
Room reg. :
The thermostat regulates room temperature only.
Room/limit :
The thermostat regulates room temperature with min.
and max. limits for floor temperature. A floor sensor
must be connected.
Regulator :
The thermostat functions as a simple regulator and no
sensors are used. The setting is a percentage.
Press
OK
and select the required application. Confirm with
OK
.
Temperature scale
Allows you to set the temperature range
within which the thermostat can be set. It is
then only possible to set a temperature within
this range in auto, comfort and manual mode.
Type OCC4/OCD4
English
Press
OK
to highlight
Min
temperature. Use the up or down but-
ton to select the minimum permissible temperature. Press
OK
and
select the maximum permissible temperature. Confirm the settings
with
OK
.
Language
Allows the language used on the display to
be changed.
Press
OK
and select the required language.
Confirm with
OK
.
Factory reset
Allows factory settings to be restored. Your
personal settings will be lost, see
Factory
settings
.
Press
OK
and choose
Reset
in the menu.
Confirm with
OK
.
Information
Displays the thermostat software version.
Back
In various parts of the menus and submenus you will find the
Back
menu item.
Use
Back
to return to the last step.
Exit
Returns to initial dispay.
Error messages
If a fault or error occurs, the thermostat will display an error code as
follows:
E0: Internal failure. The thermostat is defective. Replace thermostat.
E1: Internal sensor defective or short-circuited.
E2: External sensor defective or short-circuited.
E5: Internal overheating. Inspect the installation.
Factory settings
Preset schedule
Day 1-5
Event
Time
With floor sensor With room sensor
Day
06:00-08:00
25°C
20°C
Out
08:00-16:00
20°C
15°C
Home
16:00-22:30
25°C
21°C
Night
22:30-06:00
20°C
15°C
Day 6-7
Event
Time
With floor sensor With room sensor
Day
08:00-23:00
25°C
21°C
Night
23:00-08:00
20°C
15°C
OK
Factory reset
OK
Energy monitor
OK
Offset temp.
OK
Adaptive function
OK
Application
OK
Information