Select the required 4-event schedule and confirm with 

OK

.

For instructions on programming the time and temperature for the 
4-event schedule, see 

4-event settings

Energy monitor 

Allows you to view energy consumption for 

the past 2 days, 30 days or 365 days. 

Press 

OK

 for the chosen period. The value 

in per cent (%) shows the relative amount of 

time the heating has been on. The following figure is the cost for the 
selected period. To ensure correct calculation, check the settings for 
currency, price per kWh and load.

Currency:   Press 

OK

 and chose the required currency. 

Confirm with 

OK

.

Cost/unit:   Press 

OK

 and set the actual cost of electricity. 

The cost must be entered per kWh. Press 

OK

.

Load:  

 Press 

OK

 and enter the connected heating power. 

The value must be in watt (W). Press 

OK

.

Leave the menu by pressing 

Exit

.

Engineer settings

The Engineer settings menu contains the following options:
•   Offset temperature
•   Adaptive function
•   Application
•   Temperature scale
•   Language
•   Factory reset
•   Information

Offset temperature

If the actual measured temperature does not 
corresponding to the thermostat value, you 
can adjust the thermostat by offsetting the 
temperature.
Press 

OK

 and enter the value of the measu-

red temperature. Confirm with 

OK

.

Adaptive function

Ensures that the required temperature has 
already been reached when you get up in the 
morning or come home from work. After just 
a few days, the adaptive function will have 
automatically calculated when the heating must be turned on.
Press 

OK

 and set the function to 

On

. Confirm with 

OK

.

Application

Set the type of regulation used. 
There are 3 options:

Floor reg. :

   The thermostat regulates floor 

temperature only. A floor sen-
sor must be connected.

Room reg. :   

The thermostat regulates room temperature only. 

Room/limit :

   The thermostat regulates room temperature with min. 

and max. limits for floor temperature. A floor sensor 
must be connected.

Regulator :

   The thermostat functions as a simple regulator and no 

sensors are used. The setting is a percentage.

Press 

OK

 and select the required application. Confirm with 

OK

.

Temperature scale

Allows you to set the temperature range 
within which the thermostat can be set. It is 
then only possible to set a temperature within 
this range in auto, comfort and manual mode.

Type OCC4/OCD4     

                             English

Press 

OK

 to highlight 

Min

 temperature. Use the up or down but-

ton to select the minimum permissible temperature. Press 

OK

 and 

select the maximum permissible temperature. Confirm the settings 

with 

OK

.

Language

Allows the language used on the display to 
be changed. 
Press 

OK

 and select the required language. 

Confirm with 

OK

.

Factory reset

Allows factory settings to be restored. Your 
personal settings will be lost, see 

Factory 

settings

.

Press 

OK

 and choose 

Reset

 in the menu. 

Confirm with 

OK

Information

Displays the thermostat software version. 

Back

In various parts of the menus and submenus you will find the 

Back

 

menu item.
Use 

Back

 to return to the last step.

Exit

Returns to initial dispay.

Error messages

If a fault or error occurs, the thermostat will display an error code as 

follows:
E0:  Internal failure. The thermostat is defective. Replace thermostat. 
E1:   Internal sensor defective or short-circuited.
E2:   External sensor defective or short-circuited.
E5:   Internal overheating. Inspect the installation. 

Factory settings

Preset schedule

Day 1-5

Event

Time

With floor sensor With room sensor

Day 

06:00-08:00

25°C

20°C

Out

08:00-16:00

20°C

15°C

Home

16:00-22:30

25°C

21°C

Night

22:30-06:00

20°C

15°C

Day 6-7
Event

Time

With floor sensor With room sensor

Day

08:00-23:00

25°C

21°C

Night

23:00-08:00

20°C

15°C

OK

Factory reset

OK

Energy monitor

OK

Offset temp.

OK

Adaptive function

OK

Application

OK

Information

OK

Language

OK

Temp scale