Energy monitor
OK
Energy monitor
Allows you to view energy consumption for
the past 2 days, 30 days or 365 days.
Press
OK
for the chosen period. The value
in per cent (%) shows the relative amount of
time the heating has been on. The following figure is the cost for
the selected period. To ensure correct calculation, check the set-
tings for currency, price per kWh and load.
Currency: Press
OK
and chose the required currency.
Confirm with
OK
.
Cost/unit: Press
OK
and set the actual cost of electricity.
The cost must be entered per kWh. Press
OK
.
Load:
Press
OK
and enter the connected heating power.
The value must be in watt (W). Press
OK
.
Leave the menu by pressing
Exit
.
OK
Engineer settings
ENGINEER SETTINGS
The Engineer settings menu contains the
following options:
• Offset temperature
• Adaptive function
• Application
• Temperature scale
• Display illumination
• Selecting the sensor
• Language
• Factory reset
• Information
OK
Offset temp.
Offset temperature
If the actual measured temperature does not
corresponding to the thermostat value, you
can adjust the thermostat by offsetting the
temperature.
Press
OK
and enter the value of the measured temperature. Con-
firm with
OK
.