12
© 2014 OJ Electronics A/S
© 2014 OJ Electronics A/S
30 seconds after the last key press.
•
On:
Backlighting continuously on.
•
Heating active:
Backlighting comes on when heat is called for
by the thermostat.
Select the desired backlighting setting and confirm with
OK
.
OK
Sensor
Selecting the sensor*
Floor sensors other than the supplied
(12 kΩ/ 25 °C) can be selected with this
menu. The thermostat is preprogrammed for
4 other types:
Sensor 2 k
Ω
Sensor 10 k
Ω
Sensor 15 k
Ω
Sensor 33 k
Ω
Select the installed sensor with the arrow keys, then confirm with
OK
. The resistance characteristics of the sensor for 15 °C, 20 °C,
25 °C and 30 °C are now displayed.
If the installed sensor does not have the same characteristic as
that shown in the thermostat display, change the values at the four
listed temperatures using the arrow keys.
Confirm with
OK
to switch to the next resistance characteristic.
Select
Information
with the arrow keys, then confirm with
OK
.
The display now shows the resistance characteristic of the selected
sensor. Then confirm with
OK
. The new sensor values are now
stored in the thermostat.
*Only for thermostats with floor sensor.
NB!
If the incorrect sensor is selected there is a risk that the ther-
mostat will not be able to regulate to the desired temperatures and
therefore damage to the floor construction or covering may occur.
OK
Language
Language
Allows the language used on the display to
be changed.
Press
OK
and select the required language.
Confirm with
OK
.
OCC4/OCD4 English