18
Type WLCT
USER MANUAL
57541 09/04 - (BJ)
Type: WLCT
Fig. 1 - Buttons
Display symbols
K
I
G
H
J
F:
E:
B:
C:
D:
A:
Pin button
adjust of
clock
Reset to
factory
setting
Adjustment
down
OK -
accept
Adjustment
up
Display
G:
H:
I:
J:
K:
Automatic
mode
Manual
mode
Time and
temperature
Day number
4-event symbol
1. Getting started
Introduction
The clock thermostat type WLCT is part of the underfloor heating system type WLM. The thermostat can be set to control one single room, or it can be set
as a master to control a group of thermostats / rooms/zones.
All the thermostats that are part of that group will follow the times and temperatures programmed into the clock thermostat. For example, if the temperature
programmed in the clock thermostat is 22°C, all the thermostats / rooms belonging to that group will then also be controlled at 22°C. Depending on the
types of thermostats used you can adjust the tempe or -4°C in different rooms, giving a possible room setpoint of +18 to +26°C.
The clock thermostat can be programmed to work at different temperatures during the day allowing lower temperatures during times that the room is
unoccupied. Lower temperatures will lower your energy costs without reducing the comfort. All thermostats that are part of the group will follow any new
time or temperatures programmed in the clock thermostat.
When it leaves the factory, the thermostat has a preset program suitable for most installations.
You only need to set the clock and day, and define the thermostats / rooms that should belong to the group.
The thermostat has a pin button marked R (see fig. 1), allowing you, at any time, to reset the thermostat to the factory settings. These are listed at the end of
this manual with space for you to record your own weekly schedule.
Setting the thermostat into operation
☞
☞
☞
1-7
Press the UP ( ) or DOWN ( ) buttons to select
the correct
hours
and press OK button ( ).
Press the UP ( ) or DOWN ( ) buttons to select
the correct
minutes
and press OK button ( ).
Then press the UP ( ) or DOWN ( ) button to
select the correct
day
and press OK ( ) button.
First time power is connected the clock and day will be flashing and must be set. If you need to
adjust the time of the thermostat at a later date, insert a pin into the hole marked
(see fig. 1)
for setting of time and day. Adjustment should be made for change in summer and winter time.
Wake
Night
Out
Home
Display
Setting the room controller into operation
type W
lC
t
2
(and W
lC
t
2/
r
/HW/2)
AREA SETUP - see next page.
G:
H:
I:
Automatic
mode
Manual
mode
Time and
temperature
J:
k:
Day number
4-event symbol
Wake Out
Night Home
First time power is connected the clock and day will be flashing and must be set. If you need to adjust the
time of the thermostat at a later date, insert a pin into the hole marked (see fig. 1) for setting of time and
day. Adjustment should be made for change in summer and winter time.
Press the UP (
△
) or DOWN (
▽
) buttons to select
the correct
hours
and press Ok button ( ).
Press the UP (
△
) or DOWN (
▽
) buttons to select
the correct
minutes
and press Ok button ( ).
Then press the UP (
△
) or DOWN (
▽
) button to
select the correct
day
and press Ok ( ) button.