26
reset to fatctory settings - room controllers
Insert the room name in the box
against each Ch number, and add ON
if it is controlled by a clock thermostat.
type W
lC
t
2
(and W
lC
t
2/
r
/HW/2)
Press the pin button R for 3 secs. and the thermostat returns to
factory settings.
Remember to set time, day and area.
group
room
Ch 1
off
Ch 2
off
Ch 3
off
Ch 4
off
Ch 5
off
Ch 6
off
Ch 7
off
Ch 8
off
Ch 9
off
Ch 10
off
Ch 11
off
Ch 12
off
Ch 13
off
Ch 14
off
Example
Ch 1
Kitchen
on
Ch 2
living room
on
4-event time and temperature
own settings
Standard
WLCT2-x9
Special
WLCT2-x9/R
Special
WLCT2-x9/2
Special
WLCT2-9/HW
time
temperature
temperature
temperature
temperature
time
temperature
Day 1-5
06:00
21˚C
21˚C
21˚C
50˚C
08:00
19˚C
19˚C
19˚C
30˚C
16:00
22˚C
22˚C
22˚C
50˚C
22:30
17˚C
17˚C
17˚C
30˚C
Day 6-7
08:00
22˚C
22˚C
22˚C
50˚C
23:00
17˚C
17˚C
17˚C
30˚C
other settings
4-event sequence
-
4:52
4:52
4:52
4:52
High floor limit
temperature
-
27˚C
-
27˚C
-
Low floor limit
temperature
17˚C
17˚C
-
17˚C
-
special settings
2-step time
-
-
-
60 min
-
2-step temperature
difference
-
-
-
2˚C
-
NOTE: If more than one WLCT2 is present on the system, please copy this page.