8
21˚C
18˚C
5˚C
27˚C
17˚C
Day Temperature
Temperature set point for all room sensors not part of a room controller group.
Push (
✓
) accept and (
△
) (
▽
) to adjust the set point.
Night Temperature
When activated via an external timer, this action is valid for all room sensors connected to the master.
Night setback can also be activated on individual room sensors (WLTM & WLTD) by using the selector
switch and setting to the “night” position. A room controller (WLCT2) will automatically switch to night
setback at the times programmed into it, as will all the other
room sensors which are included in its group.
Off Temperature
All room sensors with an override switch (WLTM & WLTD) can be set to an OFF position. This is
known as a frost protection position, and if the temperature in the room shoud fall as low as 5˚C, the
heating will be enabled to prevent frost damage. The 5˚C level can be changed in the master module.
Maximum Floor limit temperature for room sensors with limit sensor (floor sensor)
Minimum Floor limit temperature for room sensors with limit sensor (floor sensor)
Max.
Min.
by using the (
△
) (UP), and the (
▽
) (DOWN) you move through the main menu into sub menus. The
description of these submenus can be seen below. If a value needs to be changed, then press (
✓
)
(CONFIRM) button once, and alter the value with the (
△
) (UP) and (
▽
) (DOWN ) buttons. Then press
(
✓
) (CONFIRM) to accept the new value.
If you wish to reset the master to factory settings, then push the (
✓
) (CONFIRM)
button for 15 sec. until the 8 outputs starts blinking. The master has now been
reset to factory settings.
Within the memory of the master, there is a room temperature Setpoint which will
apply for all rooms connected to the system. This setting is typically 21˚C when the unit
leaves the factory, but it can be increased or decreased as required. Any change will apply to all
rooms on the system unless a room controller is employed
(see next para).