22
Advanced Settings and Read-out
T
ype WLCT2
(and WLCT2/R/HW/2)
Press both UP (
△
) and DOWN (
▽
) buttons together for 3 seconds. INFO is displayed.
Continue pressing the UP(
△
) button until you reach one of the desired sub menus, PRO, Hi Li, Scal, and ArEA (For explanations, see
below. Select the sub menu with the OK ( ) button.
INFO - Information
The values of the actual measured room temperature and the fl oor temperature can be seen.
The fl oor temperature is only shown if a fl oor sensor is installed.
Software version
Room temperature
Floor temperature
Press UP (
△
) or DOWN (
▽
) button to show the different readouts.
No changes can be made here. Use the OK ( ) button to end.
PRO - 4-event sequence
It is possible to change the factory event sequence of Days 1-5 - 4 event, and days 6 & 7 – 2 event. Days 1 to 5 are usually Monday to
Friday, whilst days 6 & 7 are usually Saturday & Sunday. An EVENT is either an ON or an OFF operation. You can select from the following
sequences which are displayed in the form of a code.
4 events 5 days, 2 events 2 days indicated by Code 4:52
4 events 6 days, 2 events 1 days indicated by Code 4:61
4 events 7 days indicated by Code 4:70
2 events 7 days indicated by Code 2:70
2 events 5 days, 2 event 2 days indicated by Code 2:52
Select the required sequence with the OK ( ) button.