Hi Li - Floor sensor. Max and min allowed temperature of the floor surface
A limit sensor can be connected to the room controller.
Max limitation
is used for safety to prevent high floor temperatures. For example wooden floor constructions which should not be
allowed to exceed a maximum of 27˚C. The value can be set from 5˚C up to 55˚C. The value can also be set to OFF (adjust the
temperature to 55˚C and push button up once more).
Low limitation
is used where the temperature of the floor is required never to fall below the minimum set temperature. Example in
kitchens or bathrooms with tiles. The value can be set from 5˚C up to 55˚C. The value can also be set to OFF (adjust the
temperature to 5˚C and push button down once more). Remember the max limit temperature must be set higher than the min limit
temperature.
The limit temperatures defined in the room controller will be valid for all the room sensors with limit sensor (type WLTD-19) which
are part of the area allocated to the WLCT unit.
SCAL - Time and temperature scale selection
The maximum allowable floor temperature setting is shown. Use
the UP (
) or DOWN (
) button to increase or reduce, and OK
(
) button to accept.
The display will now show LoLi. Press OK (
) button to continue.
The minimum allowable floor temperature setting. Use the UP (
)
or DOWN (
) button to increase or reduce and OK (
) button to
accept.
You can select either ˚C or ˚F scale, and 12 or 24 hour clock as
follows:
Press UP (
) or DOWN (
) button to change settings. Confirm
the required scale with the OK button (
) button.
Adaptive function
This function enables the thermostat to calculate when it needs to switch ON so that the required temperature is reached at the set
time. With a start time of 07:00 therefore, the thermostat may switch ON as early as 06:00 so that the desired temperature of 25˚C is
achieved by 07:00. Without this function set, the thermostat will start to heat at the time you set.
}
Press the DOWN (
) button to switch between on and off.
Press OK (
) button to confirm.