PLACING AND INSTALLING EQUIPMENT
ENVIRONMENTAL CONDITIONS
THIS UNIT CANNOT BE INSTALLED IN ENVIRONMENTS WITH EXPLOSIVE GASES. THE
EQUIPMENT IS DESIGNED ONLY FOR INDOOR OPERATION.
The unit must be located in an indoor environment where the ambient is maintained less than
75
o
F/55
o
RH.
For the correct performance of the refrigerating system, it is very important to leave at least 10 cm
(4”) of free space both at the sides and back to allow proper air circulation.
Care must be taken to ensure that air drafts around the cooler
are kept to a minimum. A minimum space must be kept
between the cooler and air sources such as air conditioner
supply or return grilles, vent hoods, appliance condenser air
intake and discharge, outside doors, fans, or other air movement
devices (Fig.2).
The following horizontal distance should be considered
minimums unless special precautions are taken to prevent
interruption of the ALPA air curtain:
-5’ from appliance condenser air intake and discharge
-10’ from air conditioner supply or return grilles
-10’ from vent hood
-15’ from open doors
The location of the cooler must be kept away from sources of
heat and humidity including direct sunlight (Fig.3), toasters,
ovens, coffee warmers, other appliances condenser air
discharge, infrared heaters, or other heat generating appliances.
The unit should be leveled prior to operation.
The unit must have casters, 6” legs, or sealed per NSF
guidelines as shown in Figure 4A and 4B.
Figure 2
Figure 3
Figure 4A
Figure 4B