7_API REFERENCE MANUAL
OJMAR 113
JSON response:
{
"result": "ok",
"data":
"00051111666633090C130A040100000100006401000A03010800FE0247BD
"
}
7.3.1.3.5
FRAME FOR TEST CARD
Definition
JSON file is sent by POST with the information necessary for creating a test card
that open and closes any factory mode lock. Only available for OTS family.
Parameters
POST http://localhost:8086/serialization/testCard
Parameter
Mandatory
Data type
Possible values
lock_type
Yes
String
"OTS"
Response OK:
{
"result": "ok",
"data": "XXXXX...XXXX"
}
Response NOK:
{
"result": "error",
"code":"-1",
"message":"...."
}
Example
JSON request:
{
"lock_type": "OTS"
}