Settings, LED/Sound Indications

6

Setting

How To Use

Private Mode (Code)

• Press 

0

for 4 seconds

Factory default User code 

in private mode is “

1111

”.  

Public Mode (Code)

• Press 

1

for 4 seconds

Factory default: Public

Melody On/Off 

(Toggle)

• Press 

2

for 4 seconds

Factory default: On

Detect / Not Detect door 
status 

(Toggle)

• Press 

3

for 4 seconds

It detect or not detect the magnet in the strike. 

Factory default: Detect

Be aware to use “not detect door status mode”. No burglar alarm when opened by force.

Volume Up and Down

Press 

1

and       for 4 seconds to enter the volume control mode 

→ press 

for volume up

or press

for volume down (5 steps)

Warning alarms such as opening by force will be maximum volume level even if the volume 
is set to low.

Lock should be unlocked to change the mode.

Status

Key LED, times

Bat. LED, times

Melody (times)

Press button

Green, 1

off

1

Entering to change mode//function

Off

off

3

Incorrect passcode

Red, 4

off

4

Delete passcode

Red, 8

off

4

Unlock

Green, 3

off

4

Lock

Red, 3

off

3

Passcode deleted

off

off

6

Correct passcode

Green, 2

off

2

Incorrect passcode

Red, 3

off

6

Mode changed

Green, 3

off

2

Reset

Yellow, 1

On, 1

1

Deadbolt jammed

Yellow, 2

On, 2

4

Emergency opening alarm

Yellow, 2

On, 2

5 (10 seconds)

Battery change warning

off

On, 5

6

Passcode registered

Green, 3

off

2

Master passcode registration mode

Red (8 seconds)

off

none

User passcode registration mode

Green (8 seconds)

off

none

Battey changed

off

off

5

LED Indicator

Type

Light Colors

Purpose

Key Icon

Green, Red, Yellow

Lock Status

Battery Icon

Red

Battery Change Alarm

Summary of Contents for LF11-PL

Page 1: ...User Guide Model LF11 PL...

Page 2: ...ages 1 Features 3 2 Parts Specifications 4 3 Front Color Options 5 4 Settings LED Sound Indications 6 5 How to Use 7 6 Battery Replacement Emergency Power 8 7 Punching Installation Holes 9 8 Emergency...

Page 3: ...F11 PL provides Long battery life with mechanical type in use indicator 18 months with 3 alkaline batteries 10 times per day Stronger security through imaginary number function Emergency power supply...

Page 4: ...de Level Master User 4 12 digits Front Size 38 W X 108 4 H X 16 T mm Rear Size 66 W X 125 H X 25 T mm Battery 3 AA Alkaline Batteries 4 5V DC Battery Life Up to 18 months 10 times per day Material PC...

Page 5: ...Front Color Options LF 11PL 5 LF11 PL BK LF11 PL WH LF11 PL BR LF11 PL BL LF11 PL GR LF11 PL GY Standard color Black BK White WH Optional color Brown BR Blue BL Green GR Gray GY...

Page 6: ...maximum volume level even if the volume is set to low Lock should be unlocked to change the mode Status Key LED times Bat LED times Melody times Press button Green 1 off 1 Entering to change mode fun...

Page 7: ...User Code Public Close door enter 4 to 12 digits code Enter same code open door User code will be deleted after use 4 to 12 digits Use User Code Public Imaginary Close door any codes 4 digits code any...

Page 8: ...h new one Emergency power supply can be used when the battery is completely exhausted and the lock is not working User code is deleted when the Master code is used In Public mode the lock will stay un...

Page 9: ...Right Hand Door Punching Installation Holes 9 Left Hand Door Two Door...

Page 10: ...the hole Turn the driver count clockwise Open the door Emergency Drilling Point Emergency Opening by Force OK Digital Co Ltd 1510 Mega Bldg SKn Techno Park 124 Sagimakgol ro Seongnam si Gyeonggi do 13...

Reviews: