EN
OFZ 10011 A1
Version OK1.0 04/2015
page 19 of 22
14
Trouble shooting
Defect
Possible causes
Measures
1. Interior lights are not
working, but compressor is
running.
The light bulb is
defective.
Replace light bulb (see chapter
11).
2. There is water in the
appliance.
The water drainage
channel is blocked.
Clean the water drainage
channel and the drain pipe.
3. The cooling group starts
too often and too long.
- You have opended the
door too often.
- The air circulation
around the appliance is
obstructed.
-
Don’t open the door
unnecessarily.
- Keep free the surroundings of
the appliance.
4. The appliance does not
cool.
- The appliance is off or
not supplied with power.
-Temperature control is
regulated on
“0”
- Ambient temperature is
too low.
- Check, whether power supply
works, fuses are intact, mains
plug is correctly plugged into
the socket.
- Adjust the temperature
control.
- See chapter 6.2
WARNING
Repairs to electrical appliances may be carried out only by a qualified
technician. Repairs that are wrong or not correctly performed can cause
hazard to the user and lead to a loss of warranty.
15
Technical specification
Model
OFZ 10011 A1
Type
(Number of temperature control)
1
Defrost Cooling
Manual
Electrical connection [V/Hz]
220-240 / 50
Rated power [A]
0.55
Net weight [kg]
16
EAN no. [white]
4049011123403
Dimensions and required space, see chapter ‚Installation‘
“
*subject to change without prior notice*.