www.okinternational.com
- 4 -
P/N 7000-1370, Revision B
Safety Standards
The APR-5000 is in conformity with international safety requirements and bears
the following safety marks:
●
ETLu
●
ETLc
EMC Standards
Europe
●
EN 61000-3-2/3
●
EN
61326-1
North America
●
47 CFR part 15 ( FCC Class A ), meets Class A limits
Federal Communications Commission
This equipment has been tested and found to comply with the limits for Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in an industrial installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the system off and on, the user
is encouraged to try to correct the interference by one or more of the following
measures:
●
Reorient or relocate the receiving antenna.
●
Increase the separation between the equipment and receiver.
●
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
●
Consult the dealer or an experienced radio / TV technician for help.
Minimum Computer Operation Specification
APR-5000
Rework System
Base Unit Input Voltage
115VAC/230VAC, 50/60Hz
Base Unit Power
Consumption
2000 watts
Circuit Breaker Subzone
Heaters
15 amp
Circuit Breaker Main Unit
15 amp
Max Source Temperature
Bottom-side heater:
350°C (662°F)
Max Source Temperature
from Micro Oven
400°C (752°F)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com