42615101TH Rev.8
73 /
Oki Data CONFIDENTIAL
C5510
(1)
Open the top cover
1
.
(2)
Open the feeder unit
2
.
(3)
Remove the stay-cover-L
3
. (Tool No.2)
(4)
Remove the E-ring
4
. (Tool No.2)
(5)
Remove the shaft
5
.
(6)
Remove the Guide-Damper-L
6
and Spring
7
.
(7)
Remove the screw (golden)
8
and then the plate-lower-L
9
.
(8)
Remove the screw (golden)
0
to detach the left side cover
A
.(Tool No.1)
Figure 4-2-1-2 Left Side Cover
0
8
4
8
5
7
6
9
1
3
2
A
B
B'
B'
B
A
A'
A'
A