Oki Data CONFIDENTIAL
43163501TH Rev. 1
116 /
Priority
Level
Function
LED Blinking Pattern
PL
Status Code
ONLINE PAPER
ALERT
This appears during the NIC configuration data is
storing into the flash memory, as the setting was
changed
This appears when the NIC initialization is occurred, as
the setting was changed.
Printing request is issued to an empty tray.
Load paper.
(It takes a while until the status disappears after you
have closed the tray and the lever lifted.)
Error 491 : Tray1
Error 492 : Tray2
The paper size displaying form of the custom mode is
the same as above.
In this state, Leisus I/F : corresponding bits of both
LFTERR and LFTERR2 should be '0' (except MPTray).
Memory capacity overflows due to the following reason.
Press ON-LINE switch so that it continues. Install
expansion RAM or decrease the data amount.
- Too much print data in a page.
- Too much Macro data.
- Too much DLL data
- After frame buffer compression, over flow occurred.
Indicates that a waste toner box represented by
%COLOR% has become full and needs to be replaced.
Error 414 : Y
Error 415 : M
Error 416 : C
(Does not occur for K.)
Warning status takes effect at Cover Open/Close and
printing of about 50 copies becomes available.
Toner ends.
Error 410 : Y
Error 411 : M
Error 412 : C
Error 413 : K
Warning status takes effect at Cover Open/Close.
The signature ID of toner cartridge is not proper to the
distribution channel, but the group of signature ID is
proper (OKI regional mismatch).
As probable missing to measure the amount of toner,
the printer notifies error status and stop printing.
Error 554 : Y
Error 555 : M
Error 556 : C
Error 557 : K
Four following behavior is carried out by mode of
operation.
1. Only warning display .(This error is not
displayed).
2. Warning status takes effect at Cover Open/
Close.
3. With no automatic concentration
compensation.
4. This error is displayed and it stops.
The signature ID of toner cartridge is not proper to the
distribution channel, and the group of signature ID is
not proper (OEM channel mismatch).
Error 614 : Y
Error 615 : M
Error 616 : C
Error 617 : K
311
312
313
321
321.8
322
323
324
Error
(ONLINE)
Error
(ONLINE)
Error
491
492
Error
420
Error
414
415
416
Error
410
411
412
413
Error
554
555
556
557
Error
614
615
616
617
2
2
1
2
2
2
1
2
2
2
2
-
30993
472yy
473yy
30097
40956 (Y)
40957 (M)
40958 (C)
40029 (Y)
40030 (M)
40031 (C)
40028 (K)
40948 (Y)
40949 (M)
40950 (C)
40947 (K)
40911 (Y)
40912 (M)
40913 (C)
40910 (K)