(2) Service Call Error
When the service call error occurs, all LED of Power, Paper, and Alarm LED is high-speed
blinked at the same time at 120mS intervals. Under such a condition, it comes into "Error code
display mode" when ONLINE switch and the CANCEL switch are pressed at the same time
for more than five seconds. In this mode, the error code (decimal number of 3-digit) is
expressed by 12 bits (LED3 piece _ four times).
"Error code display mode" is ended if ONLINE switch is pressed for five times, and it returns
to the state of the LED high speed blinking. Moreover, even if the switch is not pressed for
more than 20 seconds, "Error code display mode" would be ended. ...
All LED is turned off immediately after pressing ONLINE switch (200mS), and under the
continuous condition same patterns may also recognize the switch-pressing.
When the error occurs, one example of the LED display pattern is shown as follows.
Error code display pattern of 123
The third time
■
■
Place of 1
The first time
The second time
■
Place of 100
■
■
●
■
■
●
Place of 10
The third time
●
●
■
Error code display pattern of 807
The third time
■
■
Place of 1
The first time
The second time
●
Place of 100
■
■
■
■
■
■
Place of 10
The third time
●
●
●