ES9160 MFP / ES9170 MFP
© 2012 OKI DATA CORPORATION All rights reserved
DISASSEMBLY AND REPLACEMENT
4 - 94
4.10.8
Reverse sensor (S23)
Notes:
When installing the solenoid, check if the
solenoid is installed at the center of the
scale. (The scale is longer in the center.).
Fig. 4-264
(1)
Take off the reverse unit.
(
P. 4-88 "4.10.1 Reverse unit")
(2)
Remove 3 screws and take off the plate.
Notes:
When installing, engage the slit of the
reverse gate solenoid and the lever of the
gate.
Fig. 4-265
(3)
Disconnect 1 connector, release the latch,
and take off the reverse sensor.
Fig. 4-266
Reverse gate solenoid
Window
Center
Reverse unit
Lever
Plate
Slit
Reverse sensor
Connector